background image

16

Alarm Feature Programming (Part 1)

Examine the 3 different feature charts enclosed and decide which feature will get changed. Circling the feature to

be changed will make the programming process much easier to perform.
To get into Alarm Feature Programming Mode (Part 1), repeat the following procedure:

Turn the ignition switch from the OFF position to the ON

position 3 times leaving it in the OFF position the third

time. 

Before 15 seconds has passed, push and release the valet

switch one (1) time then push the valet switch a second

time and hold it in on until 1 short and 1 long chirp or

beep is heard, then release it. You are now in Alarm

Feature Programming Part 1 programming mode.

Step 1

Step 2

OFF

ON

3X

1X + 1X (Hold)

Turn the ignition switch from the OFF position to the ON

position 3 times leaving it in the ON position the third

time. 

Before 15 seconds has passed, push and release the valet

switch two (2) times then push the valet switch a third time

and hold it in on until a long chirp or beep is heard then

release it. You are now in transmitter programming mode. 

Step 1

Step 2

OFF

ON

3X

2X + 1X (Hold)

Step 3

Press the “Lock” button on the first

transmitter until you hear a confir-

mation chirp/beep. The transmitter is

now coded into the system.

Step 4

Repeat for each additional transmitter.

Step 5

When finished, either turn off the

ignition key or wait for 15 seconds

to get out of transmitter program-

ming mode. You will hear three (3)

long chirp/beeps to indicate you are

out of the transmitter programming

mode.

OFF

Programming the Transmitter

Programming the Remote Transmitter

Important Note: This mode will only retain the last 4 remote transmitters programmed. If the transmitter memory

is exceeded, the security system will start deleting transmitters from memory in chronological order.

M8A-IM.qxp  4/26/05  15:56  Page 16

Содержание M8a

Страница 1: ...lowing two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Note The manufa...

Страница 2: ...n any forward or reverse gear Some automatic transmission vehicles mainly older GM vehicles with a purple starter wire have a mechanical type park safety switch instead of electrical safety switch The...

Страница 3: ...ust have 12 Volts when the ignition switch is turned to the start crank position only This wire must have 0 Volts in all other igni tion switch positions Note If a starter disable relay is installed t...

Страница 4: ...Connect the White wire to the parking light wire coming from the headlight switch Do not connect the White wire to the dashboard lighting dimmer switch Damage to the dimmer will result The limitation...

Страница 5: ...considerations must be made for windshield glass as some newer vehicles utilize a metallic shielded glass that will inhibit or restrict RF reception In these vehicles route the two way transceiver an...

Страница 6: ...t will in turn cause the remote start unit to shut off Black White Wire Remote Start Enable Toggle Switch Input Neutral Safety Switch Input When the Black White wire is grounded the remote start unit...

Страница 7: ...b is ON 6 If the meter reads 0 Volts until the light goes out and then reads 12 Volts you have isolated the connection wire and the wire s polarity is positive Connect this wire to the wire in the veh...

Страница 8: ...ower amounts of AC voltage Common locations for a tachometer wire are the ignition coil itself the back of the gauges engine computers and automatic transmission computers Important Do not test tachom...

Страница 9: ...e end of the 30 awg wire to pin 87 of the relay module 7 Connect the other end of the loop wire to pin 30 of relay module 8 Connect pin 86 to ignition connect pin 85 to the yellow wire of the 10 pin m...

Страница 10: ...circuit The vehicle must have an electronic door lock switch not the lock knob or key switch which locks and unlocks all of the vehicle s doors When wired for this feature pressing the disarm or unloc...

Страница 11: ...off Orange Wire 500mA Grounded Output when Armed This wire will become grounded when the alarm is armed The current capacity of this wire is 500mA This output can control a starter disable relay when...

Страница 12: ...ed Wire 200mA Timer Control Channel 5 Output See Alarm Feature Programming Part 3 Factory default setting on momentary ground This wire is built in user programmable timer output provides a ground thr...

Страница 13: ...rol Switch Blue Wire Connect to Unlock Green Wire Connect to Lock Black 3 Pin Mini Connector 3 Wire Positive Trigger Door Lock System Lock Out 12 Volts Input Unlock Out To Door Lock Control Relays Blu...

Страница 14: ...he green lock and the blue unlock wires to the vehicles one wire lock unlock wire 2 Connect our violet polarity input wire to 12v or to ground To match vehicles door lock polarity 3 The white and the...

Страница 15: ...t Wiring for 3 Wire Positive Door Lock System 87 87A 85 86 30 To 12 Volts Battery To Power Door Lock Switch Lock Unlock Wires Lock Unlock 87 87A 85 86 30 Unlock Cut Driver s Door Motor White 10 Pin Mi...

Страница 16: ...eaving it in the ON position the third time Before 15 seconds has passed push and release the valet switch two 2 times then push the valet switch a third time and hold it in on until a long chirp or b...

Страница 17: ...sive Door Locking Passive Arming with Passive Door Locking Active Arming Automatic Rearm On Automatic Rearm Off Instant Door Ajar Warning Door Ajar Error Chirp with 45 Second Check Delay 3 Hour Start...

Страница 18: ...he key in the door for about 5 or 7 sec onds and the window will close directly If your vehicle has Comfort Feature and you wish the door being locked and the window being closed automat ically at the...

Страница 19: ...Step 4 Brown White Wire 200mA Horn Output with Chirp Indicator On Black Green Wire Channel 4 Output Momentary Output Black Green Wire Ground Output During Remote Start Crank Pink Wire Two Step Door Un...

Страница 20: ...in feature channel 5 Timer Programming Mode 1C Press and release the transmitter buttons for four times 4 LED flashes 4 siren horn chirp indicates you are in feature channel 6 Timer Programming Mode...

Страница 21: ...Engine without Wait To Start Light 20 Second Warm up Timer 10 min Run Time 20 min Run Time 30 min Run Time 5 min Run Time Factory Alarm Disarm with Channel 3 On Without this Feature Constant Parking L...

Страница 22: ...Stage 2 Before 15 seconds has passed push and release the valet switch nine 9 times then push the valet switch a tenth time and hold it down until five 5 short chirps beeps one 1 long chirp beep is h...

Страница 23: ...dy for 2 seconds Step 6 Turn off the ignition to stop the engine Remember you are still in programming mode OFF Step 7 Press the button on the transmitter twice to start the vehicle If everything is c...

Страница 24: ...gine by remote Setting the crank detection to low should have solved the over cranking problem Note If the crank detection level is set to hi and the engine still will not start consistently due to a...

Страница 25: ...valet switch a tenth time and hold it down until five 5 short chirps beeps one 1 long chirp beep is heard then release it 9X 1X Hold Step 2 Press the button on the trans mitter twice to start the veh...

Страница 26: ...Operation and Feature Programming Continued After adjusting the stat timer press the button twice on the transmitter to start the engine by remote Listen for an over run or under run indication Re adj...

Страница 27: ...cs Test Mode In this test mode this system can test the Zone 2 Instant Ground Trigger the Zone 3 Door Trigger and the Zone 1 and Zone 4 Optional Sensor sensitivity The installer can save time by testi...

Страница 28: ...vice F Start the vehicle using remote transmitter a If the starter does not engage the test is complete b If the starter engages immediately step on the brake pedal to shut down the system recheck you...

Страница 29: ...hanical Neutral Safety Switch Considerations Mechanical neutral safety switch configurations differ slightly in that they do not offer the same level of safety when installing a remote start device Of...

Страница 30: ...this manual 87 87a 86 85 30 Driver s Door Pin Switch 12 V Key in Chime Module Ignition Key In Sensor Switch Closes with Key In Ignition Cylinder To Hood Pin Switch Safety Shut Down Safety IN4003 White...

Страница 31: ...e Lock Pulse or Unlock Pulse LED Indicator Brown Wire ACC Heater Output Red Wire 12 V Input Battery Red Wire 12 V Input Battery Yellow Wire Ignition 1 Output Must Connect Pink Wire Ignition 2 Output 2...

Страница 32: ...M8AIM 4 26 05 Rev D Copyright 2005 Magnadyne Corporation...

Отзывы: