8
Setting the address and the mode of operation with the DIP switches:
• Setting the mode of operation with DIP Switch 10
Switch 10 off = fx (MM) / mfx
Switch 10 on = DCC
• fx (MM)/DCC Setting the address with DIP switches (See
table starting on Page 30)
Please note:
Always do settings with the DIP switches when
there is no voltage present. The signal does not recognize the
current switch settings until the voltage is turned on.
Programming with the CS 2
fx (MM)
The CV programming must be done on the programming track.
Only one signal
may be connected to the programming track
at
a time
.
The following CVs can be changed in fx (MM): CV 39, 40, 41, and
42. With CVs 41 and 42 the value must be divided by 4 in fx (MM),
because only the values 0-80 are allowed, for example:
255/4 = 64 (rounded).
During the programming procedure, the signal light will blink.
During programming with the Central Station, by contrast the
signal is switched. After the end of the programming procedure,
the signal is set at “Go”.
The signal must be activated once before programming with
the Mobile Station 2. After that, the desired CV settings can be
changed and at the end the signal must be switched again.
The procedure for programming with the 6021 Control Unit can
be found at www.maerklin.de -> Tools & Downloads ->Tech
-
nische Informationen.
Please see the operating instructions for the control devices in
question for programming with other devices.
DCC
CV programming must be done on the programming track.
Only
one signal
may be connected to the programming track
at a
time
.
The light on the signal will blink as a check during the data
transmission.
Please see the operating instructions for the control devices in
question for programming with other devices.
CV for fx (MM) and DCC
With fx (MM) the address can be set only with the DIP switches.
The values in parentheses are factory default settings.
CV Meaning
Values
1 Address 1 - 255
1-255 (1) only DCC
9 Addresses 256 - 2040
0-7 (0) only DCC
39
PoM*
Slow movement
0 (0)
Medium fast movement
1
Fast movement
2
Medium fast movement
with bouncing
3
Fast movement with
bouncing
4
Medium fast movement
with bouncing of Arm 1
5
only with 70381
Medium fast movement
with bouncing of Arm 2
6
only with 70381