MarinAire MSBA Series Скачать руководство пользователя страница 1

Marine Air Conditioner 

User's and Installation Manual

Please read this manual before use
Keep this manual safe for future reference

Installation and after sales services should be performed 
by marine AC mechanics

MarinAire

R

R

Applies

 

to

 

all

 

MSBA

 

models

Содержание MSBA Series

Страница 1: ...r s and Installation Manual Please read this manual before use Keep this manual safe for future reference Installation and after sales services should be performed by marine AC mechanics MarinAire R R Applies to all MSBA models ...

Страница 2: ...ALLATION Installation Requirement Air Distribution Water Circulation OPERATION Control Panel Instruction Remote Control Instructions GENERAL TROUBLESHOOTING MAINTENANCE MANUFACTURERS LIMITED WARRANTY AGREEMENT 1 4 5 6 7 10 11 15 16 17 18 19 21 22 31 32 36 37 38 39 Electrical Power Galvanic Corrosion Protection 20 20 ...

Страница 3: ...ng Coaxial Heat Exchanger Tube Refrigerant Tube Air Outlet Drain Connection Charging Port Conduit Connector Drain Connection Rotatable Blower Water Outlet Filter Water Inlet Drain Connection Temperature and Humidity Sensor Drain Connection BW1 BW2 ...

Страница 4: ...g Ring Coaxial Heat Exchanger Tube Water Outlet Refrigerant Tube Water Inlet D Dr ra ai in n c co on nn ne ec ct ti io on n Rotatable Blower Drain Connection Air Outlet Drain Connection Filter Charging port Temperature and Humidity Sensor Drain Connection BW1 BW2 ...

Страница 5: ...ing Ring Coaxial Heat Exchanger Tube Refrigerant Tube Drain Connection Rotatable Blower Drain Connection Air Outlet Drain Connection Low Pressure Gauge High Pressure Gauge Water Outlet Filter Water Inlet Drain Temperature and Humidity Sensor Charging port Drain Connection BW2 BW1 ...

Страница 6: ... Holding Ring Conduit Connector Refrigerant Tube Drain Connection Rotatable Blower Drain Connection Drain Connection Low Pressure Gauge High Pressure Gauge Drain Connection Charging port Temperature and Humidity Sensor Drain BW2 Water Inlet Water Outlet Filter Air Outlet BW1 ...

Страница 7: ... 127 6 130 5 159 5 290 333 6 355 3 442 4 464 1 101 5 123 3 137 8 159 5 391 6 435 1 493 1 551 1 5 Entering Water Temperature No oper ation No oper ation No oper ation No oper ation No oper ation No oper ation No oper ation No oper ation No oper ation No oper ation Fan 360 Degree Rotatable Blower The unique design makes it very easy to rotate the blower outlet The blower can be rotated in any angle ...

Страница 8: ...illary tube cooling Evaporator High pressure High pressure Compressor Heat exchanger Water inlet Water outlet Liquid Liquid Capillary tube heating Fan Evaporator High pressure Inlet Outlet Compressor Four way valve Four way valve Outlet Inlet 3 A C DESCRIPTION Cooling mode Heating mode 6 ...

Страница 9: ...4 WIRING DIAGRAM 7 110 120V 60Hz ...

Страница 10: ...4 WIRING DIAGRAM 8 230V 60Hz ...

Страница 11: ...4 WIRING DIAGRAM 9 MSBA6C2 ...

Страница 12: ...4 WIRING DIAGRAM 10 MSBA20 MSBA24 ...

Страница 13: ...Dimensions 5 DIMENSIONS 11 MSBA6K2 Dimensions in mm 17 5 445 9 5 242 10 251 11 280 4 101 ...

Страница 14: ...Dimensions 5 DIMENSIONS MSBA6C2 Dimensions in mm 17 5 445 9 5 242 11 3 286 5 11 280 4 101 12 ...

Страница 15: ...Dimensions DIMENSIONS MSBA9 5 13 ...

Страница 16: ...Dimensions 5 DIMENSIONS 14 MSBA11 MSBA14 MSBA16 ...

Страница 17: ...Dimensions 5 DIMENSIONS 15 MSBA20 MSBA24 G 6 5 165 F 1 9 50 E 1 95 49 5 D 19 2 487 C 17 6 451 B 10 6 270 A 27 3 694 Dimensions in mm C A B D E F G 7 Diameter Duct Connection 7 Duct Connection ...

Страница 18: ...tioner and the electric box must not be placed in an explosive environment or be exposed to an explosive environment or explosive materials explosion could occur resulting in serious injury or death and or destruction of the boat This equipment does not meet requirements for ignition protection Do not install in spaces containing gasoline engines lpg cpg cylinders tanks valves regulators or fuel l...

Страница 19: ...must be built Typically the shelf may be made from 3 4 inch marine grade plywood which can be either fiber glassed or mechanically attached to the boat s sole or superstructure Do not screw directly into the hull Never place the electrical box below the air conditioning unit It is strongly recommended that you locate the return grille as low as possible and the supply air grilles as high as possib...

Страница 20: ...hrough hot and humid areas If the ducting is completely inside the air conditioned area you may use non insulated duct Using non insulated duct may cause water condensation Generally it is recommended that insulated ducts are used to eliminate condensation Sail boats generally sit lower in the water and have less glass than power boats they tend to produce more duct condensation than power boats A...

Страница 21: ...f the bilge pump fails The drain can also be connected to a condensate pump Test the installation by pouring water into the drain pan and checking for good drainage Cooling water must be supplied via a dedicated scoop type thru hull facing forwards a ball valve a strainer and a pump all of which are mounted as low as possible below the waterline Use 5 8 inch ID marine water hose Water from the pum...

Страница 22: ... and pump require the same voltage Make sure the power source is correct for the equipment 110 120V 60Hz 208 230V 50 60Hz and 220 240V 50Hz models available Power is obtained from the master Circuit Breaker Panel in the boat Power cables run from this panel to the air conditioner The air conditioner will then supply power to the pump as required A terminal strip is mounted inside the Electrical bo...

Страница 23: ...de press UP and DOWN to enter temperature setting The temperature blinks once per second In humidity and auto dehumidifying mode press UP and DOWN to enter the humidity setting The humidity blinks once per second Press UP and DOWN simultaneously for 5 seconds to switch the temperature unit to F or F to D MODE press MODE to set operation mode Auto Cooling Dehumidifying Heating Auto Dehumidifying an...

Страница 24: ...ymbol 6 Mode button 7 Timer ON button 8 High speed button 9 Mid speed button 10 Auto speed display 11 High speed display 12 Low speed display 13 Mid speed display 14 Timer OFF display 15 Auto Mode symbol 16 Fan Mode symbol 17 Dehumidifying Mode symbol 18 UP DOWN buttons 19 Unit change button 20 Timer OFF button 21 Low speed button 22 Power button Name and Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...

Страница 25: ...rature unit 2 Press the UP DOWN button to set the temperature 3 If the setting temperature is greater than the room temperature the unit will automatically switch to heating mode If the setting temperature is lower than the room temperature the unit will automatically switch to cooling mode If the setting temperature is equal to room temp the unit will run on low fan speed ...

Страница 26: ... the sea water temperature is between 60F to 95F Do not operate the unit under cooling mode when the sea water temperature is out of this range Remote Control Operation Cooling mode Press the UNIT CHANGE but ton to set the temperature unit 2 Auto fan function can only be set on LCD wall panel Once the auto fan is set the fan will stop after a while when the compressor stops The fan will run for 30...

Страница 27: ...sired humidity level can be set between 40 and 85 Once the setting level is achieved the unit will stop Fan will run every 10 minutes for 3 minutes to detect the current humidity level Use dehumidifying mode only when the sea 0 water temperature is between 60 F 0 and 95 F Do not operate the unit under this mode when the sea water temperature is out of this range Display 2 Press the UP DOWN button ...

Страница 28: ... HI TIM ER ON I TMER O FF Press the MODE button to select the fan mode 1 Press the HIGH MID LOW button to preset the fan speed 2 Fan mode Display This mode is used to circulate the air in the cabin There won t be any cooling or heating effect ...

Страница 29: ...ating function only when the sea water tempera ture is between 40F to 68F Do not operate the unit under heating mode when the sea water temperature is out of this range Display Heating mode Press the UNIT CHANGE but ton to set the temperature unit 2 Press the UP DOWN button to set the temperature 3 Auto fan function can only be set on LCD wall panel Once the auto fan is set the fan will stop after...

Страница 30: ...E C F GH HI TIM ER ON I TMER O FF Press the TIMER ON button to activate timer on function when the unit is switched off And Press one time to add hour 1 Use Timer On function to start the unit at any time within the next 24 hour Timer on Display one ...

Страница 31: ...C F GH HI TIM ER ON I TMER O FF Timer off Press the TIMER OFF button to activate timer off function when the unit is switched on And Press time to add hour 1 Use Timer Off function to turn off the unit at any time within the next 24 hour Display one one ...

Страница 32: ...e users are not on the boat Left the boat for one or more days Please note that there is a humidity sensor installed in the system Therefore desired humidity level can be set between 40 and 85 Once the setting level is achieved the unit will stop Fan will run every 60 minutes for 3 minutes to detect the current humidity level Use humidifying mode only when the sea water temperature is between 60 0...

Страница 33: ... cover of remote control hold the hook and lightly pull up 2 Insert the batteries and check if the batteries are placed in the correct position 3 Reinstall the cover 18 31 OPERATION Install and Change the Battery ...

Страница 34: ...0 temperature gets below 30 F 1 C then the compressor will be turned off to prevent the coil from freezing The unit will then display E1 This may happen on air conditioning mode or on dehumidifying mode and if the air flow is insufficient Please check and make sure that you have the appropriate size of ducting based on the capacity of your unit all the vents diffusers are fully open the return gri...

Страница 35: ...midifying mode and heating mode HEATING MODE 0 Please note that the pressures may get high if the water inlet temperature is high and above 70 F 0 21 C With the combination of the warm waters insufficient airflow and high setting temperature 0 the pressures may go above the limit even if the water temperature is below 70 F Then the pressures will rise and then the high pressure switch will cut the...

Страница 36: ... all the vents diffusers are fully open the return grill size is appropriate filters are clean and there is no obstruction to the air flow The control board is equipped with a function where an optional flow switch may be connected In case a switch is used and water flow level is low the system will shut down and display E7 error code Make sure that the pump is working the water lines as well as t...

Страница 37: ...trol panel is loose or unplugged or the cable is broken Please try to unplug the phone jacks at both ends RJ11 type jacks and plug in again Please note that using an improper cable will not work and may damage the controller The original cable has 4 leads and it has a twisted connection between the 2 ends 1 4 2 3 3 2 4 1 Generally 4 wire phone cables in the US have the same wirings A nd you may ex...

Страница 38: ...n after replacement check your pump and pump wirings If you have checked the fuse and the control panel is still not lighting up then check the transformer There are four cables coming out each two connected on both ends plugged in to the circuit board Unplug the two heads and check for continuity between the two pins with a multimeter set to Ohms If you do not have continuity please call customer...

Страница 39: ...r intake scoop for obstructions Make sure there is no leak at the connection points and also make sure that hoses are not looped kinked or crushed The hoses connecting to the unit should be 5 8 inch ID braided marine grade hoses 4 Flush the coil for about 30 minutes with a 5 solution of muriatic or hydrochloric acid and fresh water or use a premixed over the counter solution Heat Pumps utilize a r...

Страница 40: ...ither replaced or repaired return such to a factory recognized distributor dealer or service organization F O B MARINAIRE Miami FL freight collect The warranty on any part repaired or replaced under warranty expires at the end of the original warranty period This warranty does not cover and does not apply to 1 Air filters grilles fittings hoses air ducts circulation pumps refrigerant fluids oil 2 ...

Страница 41: ... liability for any damages if MARINAIRE s performance is delayed for any reason or is prevented to any extent by any event such as but not limited to any war civil unrest government restrictions or restraints strikes or work stoppages fire flood accident shortages of transportation fuel material or labor acts of God or any other reason beyond the sole control of MARINAIRE MARINAIRE EXPRESSLY DISCL...

Отзывы: