CLMD16 Configuration Guide Rev.1.1 19
Toggle a Load On / Off from Multiple Momentary Input Sources Plus a
“Toggle Network Input”
Similar to toggling a load On / Off from multiple momentary input sources, this circuit type adds
a “Toggling Network Input” signal into the circuit. When a CLMD16 ECB is in “Toggle Mode”
the ECB will toggle the state from its
current state of “On” or “Off” to the opposite state when
the following occurs: The Rising Edge or “On” detection of an ECB “Toggle Network Input” or
the Rising Edge or “On” detection of a direct ECB “Input Signal”. This operational mode will
allow for a “Toggle Network Input” which could come from a third party MFD using 127500
Load Controller PGN or any equipment running Maretron’s N2KView® software plus any
applied direct ECB “Input Signal” to toggle the ECB in harmony with each other. Tip: When an
ECB is in “Toggle Mode” a “Momentary Network Input” signal becomes unaffected by the
“Toggle Mode”.
In the following example, there will be two momentary input sources
and one “Toggle Network
Input” signal used to switch a single CLMD16 load in a Toggle fashion. One input is from a
hardwired switch that has a momentary DC (-
) signal called “Binary Event Low” and one input
is a momentary Discrete I/O input
called “Discrete I/O 1”. There is the additional influence on
the ECB of one externally set (Direct access through 127500 PGN
) “Toggle Network Input”
signal. Take note that no different action is required to setup
this circuit type than the “
Toggle a
Load On / Off from Multiple Momentary Input Sources
”
circuit above. The only difference is the
“Toggle Network Input” (shown in red) has access to the ECB setup by the message’s
origination equipment, may it be a third party MFD using 127500 Load Controller PGN or any
equipment running Maretr
on’s N2KView® software. Because the ECB is in “Toggle Mode” the
ECB’s “Input Signal” and “Toggle Network Input” will work in harmony with each other toggling
the ECB On / Off.