![Maretron MPOWER CLMD16 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/maretron/mpower-clmd16/mpower-clmd16_configuration-manual_1726975016.webp)
CLMD16 Configuration Guide___________________________________
12 CLMD16 Configuration Guide Rev.1.1
Configuring Discrete I/O Input Channels
The CLMD16 supports “Discrete I/O” inputs such as signals from Maretron’s CKM12 and
VMM6 units. Configuring the CLMD
16 to act upon “Discrete I/O” inputs starts first with
choosing which
“Discrete I/O’s” you want the CLMD16 to “watch for” or be assigned to act
upon. Every
“Discrete I/O” device has a unique “Data Instance” for the device as a whole and
“Indicator” numbers corelating with the “Discrete I/O’s” every switch. Apply the “Discrete I/O”
device
’s “Data Instance” and “Indicator” number to the CLMD16’s “Discrete I/O” input channels
to then enable these CLMD16 input channels to be used to plug directly into an ECB control
input or used as inputs to
“Switching Elements” of:
1)
“Counter”
2)
“Flash”
3)
“Latch”
4)
“Logic”
5)
“Timer”
6)
“Toggle”
Please note that if the
“Discrete I/O” device is to report the CLMD16’s ECB status, the
“Discrete I/O” device itself needs to have each of its “Indicators” to be assigned to the
CLMD16’s “Data Instance” and particular ECB it is “watching”. See below the CLMD16’s dialog
for
“Discrete I/O” input configuration.
Содержание MPOWER CLMD16