Revision 1.8.3
Page 77
Figure 61
– DSM150/DSM250/DSM410/DSM570 Remote Device Selection Screen
The “
NA
” column of the menu displays the node address the device is using.
The “
Manuf
.” column of the menu displays the manufacturer of the device.
The “
Model
” column displays the model number of the device.
The “
SN#
” column displays the serial number of the device, so that any of two or more devices of
the same manufacturer and model number may be distinguished from one another.
The “
Stat
” column indicates whether the device is currently connected to the bus and is
responding to queries (“Online”), or has been disconnected from the bus, has lost power, or for
some other reason is not responding
to queries (“Offline”).
The “
Disp
” column indicates whether data from that particular device is accepted for display by
the remote DSM150/DSM250/DSM410/DSM570 (“On”) or that the remote
DSM150/DSM250/DSM410/DSM570 ignores
data transmitted by this device (“Off”). By
scrolling to the device and pressing the Enter key (
), you may then use the Scroll Up (
)
and Scroll Down (
) keys to toggle the “Display” status for this particular device. Once you
are satisfied with the state
of the “Display” setting, press the Enter key (
) to accept the
setting.
The remote DSM150/DSM250/DSM410/DSM570 will retain information on devices that have been
removed from the bus or powered down (“Offline”) so that when they are placed back on the bus,
they will assume their prior “Display” setting.
6.8.2 Copy alarms settings from local display
It is possible to copy the alarm settings from a DSM570 unit to a remotely located
DSM150/DSM250/DSM410/DSM570. This should be done with care because if more than one Alert
Source is monitoring the same parameter, then multiple alerts will be generated when the parameter
goes out of bounds, and each one will need to be independently accepted or cancelled. Any alarms
existing on the remote DSM150/DSM250/DSM410/DSM570 will be deleted. This command will also
copy the SMS (Text) Phone Book settings. Figure 62 below shows this menu item highlighted.
Содержание DSM570
Страница 98: ...DSM570 User s Manual Page 82 Revision 1 8 3 Figure 70 DSM150 DSM250 DSM410 DSM570 Remote Device Selection...
Страница 166: ...DSM570 User s Manual Page 150 Revision 1 8 3 Figure 154 RAA100 Setting the to Sender Gauge Resistance...
Страница 223: ...Revision 1 8 3 Page 207 Figure 239 Compass Rose North Up Display...
Страница 243: ...Revision 1 8 3 Page 227 Figure 269 Favorite Screen Showing Highlighted Switch Breaker...