background image

8

After the main unit successfully displays the temperature from the outdoor 

remote sensor, the synchronization of the main unit and the outdoor remote 

sensor has been established. If the RF temperature signal is not received 

within the first five minutes, press the RF search button (B6) on the main unit 

to search for the remote temperature for another six minutes.
If the temperature is out of the measurable range, LL.L (beyond the minimum 

temperature) or HH.H (beyond the maximum temperature) will be shown on 

the display.
Press and hold the MODE button (B1) on the main unit to select the 

temperature unit, either Celsius or Fahrenheit. Press the °C/°F button (D5) on 

the outdoor remote sensor to select the temperature unit to be displayed, 

either Celsius or Fahrenheit.
Losing Synchronization of the Outdoor Remote Sensor
If the main unit received the remote temperature successfully, but now 

displays a blank value (—.-), the synchronization between the outdoor remote 

sensor and the main unit may have been lost. If this occurs, press the RF 

search button (B6) on the main unit. The main unit will attempt to receive the 

outdoor temperature for six minutes and reinitiate synchronization with the 

remote unit. If the remote temperature cannot be received, check:
 

1.  If the distance between the main unit and the outdoor remote sensor is 

 

  at least 0.9 m to 1.2 m (3 to 4 feet) away from any interfering sources, 

 

  such as computer monitors or TV sets. 

 

2.  If the main unit is in the immediate proximity of metal window frames. 

 

3.  If other electrical devices, such as headphones or speaker, operating 

 

  on the same signal frequency (433 MHz) are preventing the correct 

 

  signal transmission and reception. 

 

4.  If neighbours are using electrical devices operating on the 433 MHz 

 

  signal frequency that are causing interference.

Note: When the 433 MHz signal is received correctly, do not open the battery cover 

of either the outdoor remote sensor or the main unit, as the batteries may spring free 

from the contacts and force a false reset. Should the batteries come out, reset both 

units otherwise transmission problems may occur.
The maximum transmission range is 70 meters (230 feet) from the outdoor remote 

sensor to the main unit (in open space). However, this depends on the surrounding 

environment and interference levels. The temperature signal travels in a straight line 

from the outdoor remote sensor to the main unit. The signal will not curve around 

blocking objects. If no reception is possible despite the observation of these factors, all 
units have to be reset.

Temperature Alert function
 

1.  Press the ALERT button (B8) to activate or deactivate the outdoor 

 

temperature alert function.  

 

2.  Press the ALERT button (B8) to: 

 

  a. Activate the outdoor upper temperature alert, the icon     beside 

 

    the outdoor temperature digits will be displayed.

Содержание CL030066 Series

Страница 1: ...ATOMIC FULL CALENDAR CLOCK WITH EXTRA LARGE DIGITS AND INDOOR OUTDOOR TEMPERATURE USER MANUAL MODEL CL030066 SERIES...

Страница 2: ......

Страница 3: ...t 5 Outdoor Remote Sensor 5 Probe 6 Radio Frequency RF Transmission 6 TIME AND ALARM SETTING 6 Radio Controlled Clock 6 Time Zones and Daylight Saving Time Settings 6 Manual Setting 7 Alarm and Snooze...

Страница 4: ...utton B4 12 24 button B5 button B6 RF search button B7 RESET button B8 ALERT button C1 Wall mount hole C2 Battery compartment C3 Stand Outdoor Remote Sensor D1 Temperature display D2 Wall mount hole D...

Страница 5: ...ee the WWVB WEB page of NIST at http www boulder nist gov timefreq ENVIRONMENTAL EFFECT ON RECEPTION Like all wireless devices the receiving ability may be affected by but not limited to the following...

Страница 6: ...correct polarity and Danger of explosion is possible if batteries are incorrectly replaced Do not touch any buttons or settings on the main unit once you have installed the batteries The remote temper...

Страница 7: ...ess is stopped manually TIME AND ALARM SETTING Radio Controlled Clock After the batteries are inserted the clock automatically starts to scan for the WWVB time signal The radio control icon will flash...

Страница 8: ...unction are ON will be visible on the display to indicate daylight saving time mode Alarm and Snooze Functions 1 Press the MODE button B1 to view the alarm time ALARM TIME flashes on the display 2 Whe...

Страница 9: ...utdoor remote sensor is at least 0 9 m to 1 2 m 3 to 4 feet away from any interfering sources such as computer monitors or TV sets 2 If the main unit is in the immediate proximity of metal window fram...

Страница 10: ...he unit does not work properly 2 Press the RESET button B7 when the main unit is displaying the incorrect time even when the radio control icon is visible on the display This may happen when the exter...

Страница 11: ...ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no...

Страница 12: ...BATTERIES Please refer to your local regulations for proper disposal procedures WARRANTY Marathon Watch Company warrants this item to be free from defects in material and workmanship under normal use...