![Marantz SR6006/K1B Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/marantz/sr6006-k1b/sr6006-k1b_service-manual_1725764017.webp)
17
SPECIAL MODE
Special mode setting button
b
No.1 - 4,6 - 9 : Press the ON/STANDBY button to turn on the power while pressing both the button A and the button B at the same
time.
b
No.5 :
The AC power cord on while pressing both the button A and the button B at the same time.
b
No.10 - 13 : Press and hold both buttons A and B for over 3 second with the power turned on.
No.
Mode
Button A
Button B
Contents
1
Version display
(μcom/DSP Error Display)
ZONE
SELECT
STATUS
Firmware versions such as Main or DSP are displayed in the FL
Display. Errors are displayed when they occur. (Refer to 20 page)
2
Displaying the protection history mode
INTERNET
RADIO
ONE TOUCH
PLAY
The protection history is displayed.
3
User Initialization mode
(Installer Setup settings are not initialized.)
ZONE
SELECT
DISPLAY
Backup data initialization is carried out.
(Installer Setup settings are not initialized.)
4
Factory Initialization mode
(Installer Setup settings are also
initialized.)
M-DAX
DISPLAY
Backup data initialization is carried out.
(Installer Setup settings are also initialized.)
5
Mode for switching tuner frequency step
(U/N model only)
PURE
DIRECT
STATUS
Change tuner frequency step to FM:200kHz/AM:10kHzSTEP
6
Mode for preventing remote control
acceptance
PURE
DIRECT
ONE TOUCH
PLAY
Operations using the remote control are rejected.
(Mode cancellation: Turn off the power and execute the same
button operations as when performing setup.)
7
Panel lock mode
PURE
DIRECT
DISPLAY
Operations using the main unit panel buttons or the master volume
knob are rejected.
8
Panel lock mode
(Master volume is not locked.)
PURE
DIRECT
STATUS
Operations using the main unit panel buttons are rejected.
9
Cancellation of panel lock mode
PURE
DIRECT
ZONE
SELECT
Panel lock mode is cancelled.
10 Diagnostic mode
ZONE
SELECT
PURE
DIRECT
This mode is used for confirming the Video and Audio (signal)
paths. (Troubleshooting)
The signal paths of the set can be easily confirmed after repair.
11 Memory Backup
M-DAX
STATUS
Backup of DUAL BACKUP MEMORY is performed. (Refer to 24
page)
12 Memory Recovery
M-DAX
DISPLAY
Recovery of DUAL BACKUP MEMORY is performed. (Refer to 24
page)
13 Memory Backup Clear
M-DAX
ZONE
SELECT
Backup of DUAL BACKUP MEMORY is cleared. (Refer to 24 page)
14 Installer Setup mode
ZONE
SELECT
M-DAX
Access the Remote Maintenance mode via the internet.Installer
Setup is displayed on GUI/Option Menu.
b
Refer to AVR_RemoteMaintenance_.pdf of SDI.
NOTE:
If "SUB LOG display mode"(
b
) is displayed on the fluorescent display, the set is in the special developer's mode and the
RS-232C communications are not possible.
Turn on the power, then press and hold down the "PURE DIRECT" and "STATUS" buttons for over 3 seconds to turn off
"SUB LOG display mode"(
b
) on the display. RS-232C communications are now enabled.
ON/STANDBY
PURE
DIRECT
ZONE
SELECT
DISPLAY ONE TOUCH
PLAY
M-DAX
STATUS
INTERNET
RADIO
(
b
)
Содержание SR6006/K1B
Страница 14: ...14 3 Disconnect the connector wire Remove the screws 4 Remove the screws CN931...
Страница 60: ...Personal notes Personal notes 60...
Страница 81: ...81 I2C communication wave form CH1 CLK CH1 DATA...
Страница 157: ...157 Personal notes Personal notes...
Страница 167: ...167 R5F3650KNFB HDMI IC231...
Страница 176: ...176 W9864G6JH 6 HDMI IC409 W9864G2IH Publication Release Date Aug 28 2009 4 Revision A03 4 PIN CONFIGURATION...
Страница 179: ...179 MX29LV160DBTI 70G HDMI IC410 MX29LV160DBTI 70G Block Diagram...
Страница 180: ...180 AK4424ET HDMI IC455 IC457 AK4424ET Block Diagram...
Страница 181: ...181 AK5358BET HDMI IC451 AK5358BET Pin Function...
Страница 185: ...185 W9825G6JH 6 HDMI IC392 W9825G6JH 6 Pin Function...
Страница 192: ...192 NJW1194A AUDIO IC484 IC489 BLOCK DIAGRAM...
Страница 193: ...193 2 FL DISPLAY VFD GP1261AI FRONT Z1002 PIN CONNECTION PATTERN DETAIL...
Страница 225: ...225 Personal notes...