Make sure to initialize this unit after replacing the microcomputer or any peripheral equipment, or the
digital PCB.
1. Press the power operation button to turn off the power, and remove the AC plug from the socket.
2. Insert the AC plug while pressing buttons "
INPUT
" and "
BACK
" together, and wait for more than 3
seconds.
3. Release buttons "
INPUT
" and "
BACK
" when the power indicator turns green.
4. All lights on the display illuminate for 4 seconds. The power indicator lights up in orange.
5. All lights on the display turn off for 2 seconds.
6. "
Factory Reset
" is shown on the display for 5 seconds.
The settings for the Installer Setup is also initialized.
Network function settings are not initialized.
NOTE
: • If the unit fails to enter the service mode in step 6, repeat the procedure from step 1.
• Initializing the device restores the customized settings to the factory settings. Write down
your settings in advance and reconfigure the settings after initialization.
Use network initialization mode to initialize the network related settings.
1. Press the power operation button to turn off the power, and remove the AC plug from the socket.
2. Insert the AC plug while pressing button "
POWER
", and wait for more than 3 seconds.
3. Release button "
POWER
" when the power indicator turns green.
4. Once "Special model" is displayed, press "
CURSOR
f
", select "
Initialize
" then press the "
Enter
"
button.
5. All lights on the display turn off for 5 seconds.
6. "
Initialized
" is shown on the display for 5 seconds.
・All settings, including network function settings, are initialized.
7. Wait for more than 90 seconds after "
Initialized
" is displayed and then turn the power off.
(During this time, start and initialize the network devices.)
BACK
INPUT
X
ENTER
Indicator
Cursor▼
Initializing this Unit
POST-SERVICE PRECAUTIONS
s
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating
7