2-2. 232C Standby Clear Mode
2-2.1. Actions
Switches from 232C standby mode to normal standby mode.
2-2.2. Starting up
While holding down buttons "
ZONE SELECT
" and "
BACK
" simultaneously, press the power button to turn on the pow-
er.
Select the "
3.RS232C RESET
" using the "
CURSOR
f
/
d
" button, then press the "
ENTER
" button then to confirm.
Switches from 232C standby mode to normal standby mode.
2-3. Operation Info Mode
2-3.1. Actions
This mode enables the unit to display the accumulated operating time, power on count and each protection count.
2-3.2. Starting up
While holding down buttons "
ZONE SELECT
" and "
BACK
" simultaneously, press the power button to turn on the pow-
er.
Select the "
4. OP INFO
" using the "
CURSOR
f
/
d
" button, then press the "
ENTER
" button to confirm.
2-3.3. Operations
Press the "
STATUS
" button after starting up this device in Operation Info mode.
The following information is displayed in the following order.
(a) Accumulated operating time
FLD
L1
O p e r a t i o n
T i m e
L2
T o t a l :
H
"
STATUS
"
↑ Time display
(b) Power on count
FLD
L1
P o w e r
O n
T i m e
L2
T o t a l :
"
STATUS
"
↑ Count display
(c) DC / ASO Protection count
FLD
L1
P r o t e c t i o n
T i m e
L2
D C :
/ A S O :
"
STATUS
"
(d) CURRENT Protection count
FLD
L1
P r o t e c t i o n
T i m e
L2
C u r r e n t :
"
STATUS
"
(Returns to normal display)
68
Содержание AV7702mkII
Страница 8: ...Personal notes 8 ...
Страница 190: ...2 FL DISPLAY FLD 17 BT 40GINK FRONT FL601 PIN CONNECTION GRID ASSIGNMENT Y2 q 190 ...
Страница 191: ...ANODE CONNECTION 191 ...
Страница 192: ...FLD GP1261AI FRONT FLT4400 PIN CONNECTION PATTERN DETAIL 192 ...
Страница 193: ...ANODE CONNECTION 193 ...
Страница 208: ...H DAM 15 REF No Part No Part Name Remarks Q ty New Ver RY940 942 943682000810S RELAY BC3 12H DC12V 2C2P CSL4A016ZU 3 ...