NOTE FOR SCHEMATIC DIAGRAM
WARNING:
Parts indicated by the
z
mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.
CAUTION:
Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If
the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set
is defective.
WARNING:
DO NOT return the set to the customer unless the problem is identified and remedied.
NOTICE:
ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHM
ALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNLESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO FARAD. EACH
VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT
PRIOR NOTICE.
NOTE FOR PARTS LIST
1. Parts indicated by
"nsp"
on this table cannot be supplied.
2. When ordering a part, make a clear distinction between "1" and "I" (i) to avoid mis-supplying.
3. A part ordered without specifying its part number can not be supplied.
4. Part indicated by "
★
" mark is not illustrated in the exploded view.
WARNING:
Parts indicated by the
z
mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.
INSTRUCTIONS FOR HANDLING SEMI-CONDUCTORS AND OPTICAL UNIT
Electrostatic breakdown of the semi-conductors or optical pickup may occur due to a potential difference caused by
electrostatic charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1 MΩ) that is properly grounded to remove any static electricity that may be charged
on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate with proper grounding (1 MΩ) on the workbench or other surface,
where the semi-conductors are to be placed. Because the static electricity charge on clothing will not escape through the
body grounding band, be careful to avoid contacting semi-conductors with your clothing
<Incorrect>
CBA
Grounding Band
Conductive Sheet or
Copper Plate
1MΩ
1MΩ
<Correct>
CBA
7
Содержание AV7702mkII
Страница 8: ...Personal notes 8 ...
Страница 190: ...2 FL DISPLAY FLD 17 BT 40GINK FRONT FL601 PIN CONNECTION GRID ASSIGNMENT Y2 q 190 ...
Страница 191: ...ANODE CONNECTION 191 ...
Страница 192: ...FLD GP1261AI FRONT FLT4400 PIN CONNECTION PATTERN DETAIL 192 ...
Страница 193: ...ANODE CONNECTION 193 ...
Страница 208: ...H DAM 15 REF No Part No Part Name Remarks Q ty New Ver RY940 942 943682000810S RELAY BC3 12H DC12V 2C2P CSL4A016ZU 3 ...