JOG—
Decreases the value in a 16-bit PLC register by a step value each time it is pressed. If the
key is held down, then it will continue to decrease by the step value at a predefined rate.
Dec. value:
Amount of the step value. Range: 1 to 32767
Bottom limit:
The lowest range allowed. Range: -32768 to 32767
JOG delay:
The amount of delay after the key is held down before automatic decrementing occurs.
Range: 0.1 to 1.5 seconds
JOG speed:
The rate at which the automatic decrementing occurs.
Range: 0.1 to 1.5 seconds
Set at window
open
Automatically places a constant value into a PLC register when the window that the part is
located in is opened.
Set value:
Constant used. Range: -32768 to 65535
Set at window
close
Automatically places a constant value into a PLC register when the window that the part is
located in is closed.
Set value:
Constant used. Range: -32768 to 65535
Periodical JOG++
Continuously increases the value in a 16-bit PLC register by a step value at a predefined
rate as long as the window that the part is located on is open. This is very similar to a self
resetting timer.
Inc. value:
Amount of the step value. Range: 1 to 32767
Upper limit:
The upper range allowed. Range: -32768 to 32767
Break time:
The rate at which the automatic incrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Periodical JOG—
Continuously decreases the value in a 16-bit PLC register by a step value at a predefined
rate as long as the window that the part is located on is open. This is very similar to a self
resetting timer.
Dec. value:
Amount of the step value. Range: 1 to 32767
Bottom limit:
The lowest range allowed. Range: -32768 to 32767
Break time:
The rate at which the automatic decrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Periodical bounce
Automatically increases the value in a 16-bit PLC register by a step value at a predefined
rate as long as the window that the part is located on is open. When the upper limit is
reached, the value automatically decreases until it reaches 0, then repeats the process
continuously.
Inc. value:
Amount of the step value. Range: 1 to 32767
Upper limit:
The upper range allowed. Range: 1 to 32767
Break time:
The rate at which the automatic incrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Step up
Continuously increases the value in a 16-bit PLC register by 1 from a specified low limit at
a predefined rate as long as the window that the part is located on is open. When the high
limit is reached, the process repeats starting at the low limit again.
Low limit:
The lowest range allowed. Range: -32768 to 65535
Upper limit:
The upper range allowed. Range: -32768 to 65535
Break time:
The rate at which the automatic incrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Step down
Continuously decreases the value in a 16-bit PLC register by 1 from a specified high limit
at a predefined rate as long as the window that the part is located on is open. When the
low limit is reached, the process repeats starting at the high limit again.
Low limit:
The lowest range allowed. Range: -32768 to 65535
Upper limit:
The upper range allowed. Range: -32768 to 65535
Break time:
The rate at which the automatic decrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Set at window
maximized
Automatically places a 16-bit constant value into a PLC register when the window that the
part is located in is maximized.
Set value:
Constant used. Range: -32768 to 65535
1010-1001a, Rev 02
Rep re senting Data with Graph ics Ob jects
181
Содержание Silver HMI504T
Страница 1: ...1010 1001A Rev 02...
Страница 20: ...1010 1001a Rev 02 16 Silver Series Installation Operation Manual OIT to PC Serial Port Pin Assignments...
Страница 32: ...1010 1001a Rev 02 28 Silver Series Installation Operation Manual...
Страница 128: ...1010 1001a Rev 01 124 Silver Series Installation Operation Manual...
Страница 156: ...1010 1001a Rev 02 152 Silver Series Installation Operation Manual...
Страница 166: ...1010 1001a Rev 02 162 Silver Series Installation Operation Manual...
Страница 216: ...1010 1001a Rev 01 212 Silver Series Installation Operation Manual...
Страница 251: ...1010 1001a Rev 02 Macros 247 Set Bit Objects Attributes Dialog Project Example of Add 2...
Страница 264: ...End Macro_Command 1010 1001a Rev 02 260 Silver Series Installation Operation Manual...
Страница 268: ...1010 1001a Rev 01 264 Silver Series Installation Operation Manual...