background image

1010-1018 Rev 12                                                                          www.maplesystems.com

Introduction

Thank you for purchasing a Maple Systems HMI5000L Series graphic 
industrial operator interface terminal. This booklet describes the steps 
necessary for installing the following models:

HMI5043L

HMI5043LB

HMI5043DL

HMI5070NL

HMI5070L

HMI5070LB

HMI5070DL

HMI5071L

HMI5097DXL

HMI5097NXL

HMI5100L

HMI5102L

HMI5103L

HMI5120XL

HMI5121XL

HMI5150XL

The HMI5000L Series touchscreens are configured using the 
EasyBuilder Pro Software.

For information on programming and configuring the HMI, please refer to 
the 

EasyBuilder Pro Programming Manual

 available for free download 

on the Maple Systems website in the Support Center.

For additional information, please refer to the Support Center

 

section of 

the Maple Systems website, www.maplesystems.com/support.

The Support Center provides links to information such as Software 
Downloads, Manuals, FAQs, Technical Notes, Training Videos, Sample 
Projects, Controller Information Sheets, Controller Cables, and more.

HMI5000L Series

Installation Guide

Содержание HMI5000L Series

Страница 1: ...touchscreens are configured using the EasyBuilder Pro Software For information on programming and configuring the HMI please refer to the EasyBuilder Pro Programming Manual available for free downloa...

Страница 2: ...l material in the container against the packing list Maple Systems will not accept responsibility for shortages against the packing list unless notified within 30 days The equipment and accessories we...

Страница 3: ...liance The HMIs have been tested to conform to European CE requirements which meet or exceed the noise emissions and immunity requirements as set forth in the EN55022 Emissions and EN55024 Immunity st...

Страница 4: ...tional electrical standards when installing the HMI Failure to comply with these restrictions could result in loss of life serious personal injury or equipment damage Warning Do not connect the HMI to...

Страница 5: ...wer Supply Selection The power supply used to power the HMI should provide an output of at least 24 VDC 20 measured at the HMI power connector HMI5043DL should be powered with 10 5 28VDC only A DC reg...

Страница 6: ...und strap Quiet ground isolated AC Power Line Filter HMI Power Supply Shielded power cable Control panel is tied to a reliable earth ground 2 1 3 4 5 rear side HMI5100L 1 rear side HMI5070L 2 2 3 1 Al...

Страница 7: ...round Note If the control panel is made of a non conductive material it is essential that the chassis ground terminal of the HMI is connected to a clean earth ground point located close to the panel C...

Страница 8: ...the power cable from the HMI to the power supply The power cable should not be any longer than necessary 2 Install the cable wires referencing the chart below with colors shown for Maple Systems Cable...

Страница 9: ...es pits and other features that prevent the gasket from sealing properly If the panel or mounting surface is not uniform thick flat stiff or smooth enough then a sealant such as silicone may be requir...

Страница 10: ...cluded with the EasyBuilder Pro software must be installed when downloading from the PC to the HMI via USB connection Caution When connecting two powered devices via USB a difference in potential can...

Страница 11: ...arrow icon located in the lower right corner of the screen 3 Click the gear icon to enter the system settings menu 4 When prompted enter the system password default 111111 5 Navigate to the Network ta...

Страница 12: ...EN Hide System Toolbar OPEN OPEN SHORT OPEN Boot Loader mode OPEN OPEN OPEN SHORT Reserved OPEN OPEN OPEN OPEN Normal operation Note Place a jumper cap between the respective header pins to set the ju...

Страница 13: ...up remove power An internal fuse except 4 3 display models will prevent damage if the polarity of the DC power is incorrect Check wiring to ensure proper connections and try to power up again USB Sti...

Страница 14: ...2 wire 1 RX DATA 2 RX DATA 3 TX 4 TX 5 GND 6 TXD 7 DATA 8 DATA 9 RXD Pin COM1 232 RS 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 HMI XL 5150 DE9S DE9P HMI5100L HMI HMI LB 5070L 5070 HMI XL 5121 Pin COM1 48...

Страница 15: ...485 4W RS COM2 COM3 485 2W RS RS 485 4W COM3 1 DATA RX 2 DATA RX 3 TX 4 TX 5 GND 6 DATA RX 7 DATA TX 8 DATA TX 9 DATA RX Pin COM1 RS 232 232 RS COM3 1 2 RXD 3 TXD 4 5 GND 6 7 RTS TXD 8 CTS RXD 9 GND P...

Страница 16: ...Enter the desired IP address or select Obtain an IP Address Automatically to enable DHCP 4 Navigate to the LAN2 tab 5 Enter the desired IP address or select Obtain an IP Address Automatically to enab...

Страница 17: ...n addition to the standard RJ45 Ethernet port Supported Wi Fi modes are IEEE 802 11 b g n with WPA PSK WPA2 PSK encryption Wi Fi is off by default To enable and configure Wi Fi 1 Enter the System Sett...

Страница 18: ...10 Tap Close to exit the Wi Fi setting window 11 Click Apply to save the changes and OK to exit the system settings menu 12 The updated IP addressing will appear in the Wi Fi tabs of the System Inform...

Страница 19: ......

Страница 20: ...12 www maplesystems com 2019 Maple Systems Inc All rights reserved Maple Systems Inc 808 134th Street SW Suite 120 Everett WA 98204 7333 Phone 425 745 3229 Email support maplesystems com Web www mapl...

Отзывы: