Maple Armor FW6308-CLA1 Скачать руководство пользователя страница 1

Maple Armor

 

FW6308-CLA1 

Intercom 

3G Wireless Building door phone

 

DOC-FW6308-CLA1

Operating/Programming/Installation Manual

 

Содержание FW6308-CLA1

Страница 1: ...Maple Armor FW6308 CLA1 Intercom 3G Wireless Building door phone DOC FW6308 CLA1 Operating Programming Installation Manual ...

Страница 2: ...tware on PC 5 SMS FUNCTIONS 6 1 ADMINISTRATOR SMS TO MODIFY USER INFORMATION 6 2 ADMINISTRATOR SMS TO MANAGE ACCESS CONTROL 6 3 ADMINISTRATOR SMS TO MANAGE DOOR CONTACT 6 4 DOOR COMTACT ALARM 6 5 ADMINISTRATOR SMS TO MODIFY UNLOCKING CODE 6 1 Administrator SMS to modify user information Erreur Signet non défini 2 Administrator SMS to manage access control Erreur Signet non défini 3 Administrator S...

Страница 3: ... set room number each four digits number 8 Visitors dial room number to call resident outdoor station will call resident phone automatically If thefirst phone no one answer after 30s it will call the second one automatically and then the third one 9 During calling could unlock door through phone press 10 Visitors can search user room number via username and also could check all resident name list ...

Страница 4: ...o call the user directly press exit the call If did not find the name it will show II Search tenant name list Press Name List Interface it will show press is for the previous name press it is for the next name Exit 1 7 Dial Press to call the user press 2 Set up to exit the calling Note can t exit when record pic before calling Administrator could set and modify unlock code and administrator code t...

Страница 5: ...l show you then press move to next page Room NO now could input 2 3 new resident information Also could SMS to modify the user information Query Press to enter the page of searching user information basic on room number Pls input room NO input the room No you want to check Then it will display OK could get ID Index username and phone numbers Press to return previous page or it will back main menu ...

Страница 6: ...ew folder contact on SD Card copy the document contact_info txt under the folder if exist same document please instead the old one Finally input the Memory card on GSM device Please note 1 If the second time add contact data do not need to create the file contact again on Memory card 2 Please edit the users details according to the device capacity 3 Could set private unlock password on the softwar...

Страница 7: ...age access control Delete Card 06 12 digits ID card number If less 12 digits please add the digits 0 to the front Register new card 07 12 digits ID card number If less 12 digits please add the digits 0 to the front III Administrator SMS to manage Door contact 1 Check Door switch status send 08 to the panel if the door is closed it will send SMS back with door close if the door is opened it willsen...

Страница 8: ...ally For example Need to set 30 times password with 654321 then SMS 13 030 654321 Will get back message set success means set success Or the message will be set fail 2 SMS set the time for Temporary password 14 XXXX XX XX XX XXXX XX XX XX CCCCCC XXXX XX XX XX means Year Month Day Time CCCCCC means 6 digits temporary password Please Note Set the time for Temporary password Maximum 6 times From the ...

Страница 9: ...8 Installation Instructions 1 Product wiring diagram SD card socket SIM card socket Main circuit board The button for Going out Access control Speaker ...

Страница 10: ...9 2 Dimension Front Back Side 3 Against the wall box and Hole Size Front Side against the wall box hole size ...

Отзывы: