background image

3. External 

Grille

 

Locate the position for the external grille and cut a 

 

130mm diameter hole. Connect one end of the 

 

125mm diameter duct to the spigot of the external 

 grille.

 Note:

 Since the length of each duct is 3.0m, make 

 

sure the centre of the installation hole is no more 

 

than 3.0m from the vent.

 Note: 

In order to get an effective ventilation, it is 

 

suggested that the duct is no more than 3.0m in 

 length.

 Caution: 

Use appropriate safety PPE when cutting 

 

fibre cement products.

4. Wiring

 

Connect one end of the interconnecting wire to the wall switch panel, and bring the other end 

 

out of the hole in the ceiling. Open the terminal block cover on the unit’s housing, make the 

 

connection as per the wiring diagram instruction below, then reposition the terminal block 

 

cover. Press excess wire back into the ceiling.

 Note:

 Ensure that the power is isolated before carrying out any work on electrical installations. 

5.  Fit the tie-in into the fan outlet in the housing with 
 

Ø125mm duct clip. Fit the in-house end of the duct to 

 

the fan outlet, and fix the end with duct tap.

 Note:

 Keep the route as straight as possible.

6.  Position the housing into the hole

 

Insert the unit into the square hole being sure to pull the

 

side clips inward so that the body can pass through the

 

hole without damaging the plaster. Rotate the swing

 

clips to hold motor body in place then tighten screw to

 

let the clip clamp onto the ceiling board.

7. Final 

Installation

 

1. 

Reconnect the LED downlight. 

 

2. 

Replace the Fascia

 

 

Replace the fascia and retaining springs.

 

3. 

Replace the Lamps

 

 

Ensure the lamps are tightened sufficiently to make 

 

 

good electrical contact. Clean the lamps and fascia.

 

4. 

Fix the Switch Panel to the Wall

 

 

Fit the switch panel onto the wall, ensuring that in 

 

 

this position it is not subjected to splashed water.

   Note:

 The switch wiring should be routed inside the 

 

 

wall. If it is necessary to run the wiring on the outside 

 

 

of the wall, use a suitable conduit and fixings to 

 

 

properly locate and hold the wiring used.

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE

Read and save these instructions!

Please take this card as hole cutting template 320mm x 320mm

SATIN

FAN6882/FAN6883

Dear customer,

Thank you for selecting MANROSE. Please read all instructions before commencing installation.

WARNING - ALL WIRING MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN

1. 

Use this SATIN heat-fan-light unit only as described in this manual. Any other use not 

 

recommended by the manufacturer may cause fire, electric shock, or injury to persons. 

 

If you have questions, contact the manufacturer or local agent.

2. 

All wiring must be carried out by a Licensed Electrician in accordance with all national wiring   

 codes.
3. 

Make sure the power is isolated before installing.

4. 

When cutting into the ceiling, do not damage electrical wiring and other hidden utilities. 

5. 

The SATIN heat-fan-light unit must be properly earthed.

6. 

The lamps are hot when in use. Do not touch the infrared lamps when in use.

7. 

Precautions must be taken to avoid the back-flow of gases into the room from the open flue of  

 

gas or other open-fire appliances when mounted in outside walls or soffits.

8. 

The SATIN heat-fan-light unit must be isolated from the power by means of a plug or a switch  

 

capable of disconnecting all poles with a contact separation of at least 3mm in each pole.

9. 

The power cable must be rated for a minimum 10A inductive load.

10.  The appliance is not intended for use by persons (including children) with reduced physical, 
 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given  

 

supervision or instruction concerning use of the appliance by a person responsible for their safety.

11.  Children should be supervised to ensure that they do not play with the appliance.

IMPORTANT CONSIDERATIONS BEFORE INSTALLING

A few minutes of planning can make a big difference to the installation time and ultimate 
satisfaction with the functioning of the unit.
1. 

The unit should not be installed directly above a shower or bathtub. The unit must not be 

 

installed in a position where water may splash onto the lamps.

2. 

The unit must not be installed beneath a fixed electrical socket.

3. 

The unit is designed for installation in flat ceilings only. Do not mount it on a sloping ceiling or a 

 vertical 

wall. 

4. 

The infrared lamps are most effective when you are standing directly beneath them, so generally

 

the unit would be mounted above a place where you would stand to dry yourself.

5. 

For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being 

 

extracted must be able to enter the room. Generally this air would be drawn under the door. 

 

If the room is airtight, the fan will not exhaust air efficiently.

6. 

Before commencing any cutting, check in the ceiling space that there are no obstructions such 

 

as ceiling joists and that there is sufficient height clearance for the housing. Check that the 

 

electrical wiring can be routed from the wall switches to the mounting location.

INSTALLATION
1.   Locating the SATIN Heat-Fan-Light unit

 

For the purpose of obtaining the best heating effect from the lamps there should be at least 

 

2.3m overall height from unit to ground.

2. 

Prepare the ceiling

 

Select the mounting position for the unit. 

 

Check that it is possible to route the ducting 

 

from the unit to the outside of the house. 

 

This will generally be to the soffit but can be 

 

to a wall outlet location (as pictured).

 

Use this hole-cutting template to mark the 

 

hole on the ceiling. Make sure a distance 

 

between the edges of the unit and wall is 

 

no less than 250mm. There should be a 

 

minimum 220mm vertical distance between 

 

the ceiling and roof.

sealant

grille

heat-fan-light

duct

infrared lamps

wall

ceiling

fascia

ceiling joist

duct clip

320mm

320mm

N

L

LIGHT

FAN

HEAT

HEAT

LED power
 driver

thermostat

N

L

K4

K3

K2

K1

~

M

C

Motor

heat lamp

L

WARNING

Failure to connect a permanent live connection to the 

Heat-Fan-Light will result in failure of critical safety features

Отзывы: