Installation and Wiring 

Instructions

Switch off mains supply before making any electrical 

connections.
Installation must be supervised by a qualified 

electrician. 

This appliance can be used by children aged from 8 years 

and above and persons with reduced physical, sensory and 

mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning the 

use of the appliance in a safe way and understand the hazards 

involved. 
Children shall not play with the appliance. 
Cleaning and user maintenance shall not be made by children 

without supervision.
Precautions must be taken to avoid the back-flow of gases 

into the room from the open flue of gas or other open-fire 

appliances when mounted in outside windows or walls.
Fan must be disconnected from electrical power before any 

maintenance is carried out.

Location – inline fans

When installing this fan’s ducting through an 

external wall, an external wall grille must be fitted 

at all times.

This fan should be fitted to ducting with a 

minimum duct length of at least 500 millimetres 

both sides of the fan.
Where ducted fans are used to handle moisture-

laden air, such as a bathroom, a condensation 

trap should be fitted in any vertical exhaust ducts.
When using flexible ducting, ensure it is pulled 

taut. All ducting should be angled towards the 

external grille.

Ducting passing through cold voids should be 

insulated. If the fan and duct extract grille is 

installed in a room containing a fuel burning 

appliance, the installer must ensure that the air 

replacement is adequate for both the fan and the 

fuel burning appliance.

Wiring

 Switch off mains supply before making electrical 

connections. If in any doubt contact a qualified 

electrician.

These units are for fixed wiring only. A flexible 

cord must not be used. All wiring must be fixed 

securely and the cable to the fan should be a 

minimum of 1mm2 in section.

All wiring must comply with current I.E.E. 

Regulations or local regulations if outside the UK.

A double pole fused spur having contact 

separation of at least 3mm in all poles must be 

used and fitted with a 3A fuse.

This fan is double insulated and does not require 

an earth connection.
The fan should not be accessible to a person 

using either the shower or the bath.

Содержание 100SLKTC

Страница 1: ...a minimum duct length of at least 500 millimetres both sides of the fan Where ducted fans are used to handle moisture laden air such as a bathroom a condensation trap should be fitted in any vertical...

Страница 2: ...n Falls zur Ableitung von Luft mit hoher Feuchtigkeit wie z B in B dern Mantelpropeller eingesetzt werden sollte ein Kondensatsammelbeh lter in vertikale Abluftkan le integriert werden Elastische Kan...

Страница 3: ...ns 500 millim tres des deux c t s du ventilateur En cas d utilisation de ventilateurs car n s pour traiter l air humide comme dans les salles de bains par exemple installer un pi ge de condensation da...

Страница 4: ...mniej 500 milimetr w po obu stronach wentylatora W przypadku u ycia wentylator w z kana ami do odprowadzania wilgotnego powietrza np w azience nale y zamontowa skraplacz wilgoci w ka dym pionowym kana...

Страница 5: ...ores entubados se utilizan para gestionar aire cargado de humedad como en un cuarto de ba o deber a instalarse una trampa de condensaci n en todos los tubos de escape verticales Si utiliza tubos flexi...

Страница 6: ...ilador Quando se utilizarem ventiladores com conduta para processar ar carregado de humidade com o de casas de banho dever instalar se um coletor de condensa o em todas as condutas de escape verticais...

Страница 7: ...lo unde conductele sunt folosite pentru evacuarea umezelii cum ar fi b i pe oricare din conductele verticale de evacuare se va monta o trap de condens Acolo unde se folosesc conducte flexibile asigura...

Страница 8: ...500mm 500mm x2 x10 x10 x3 x10 x10 100mm x 115mm x 102mm 120mm x 135mm x 120mm x mm 100mm y 110mm 120mm y 130mm y mm 100T 100SLKTC 120TC 1...

Страница 9: ...x4 x2 2 3 4 5 6...

Страница 10: ...end Nullleiter Geschaltete Phase Phase permanente Neutre Phase commut e Pod sta ym napi ciem Neutralne Pod prze czanym napi ciem Bajo tensi n permanente Neutro Bajo tensi n conmutada Sempre ativo Neut...

Страница 11: ...SL N SL L 3A max SL N SL L 3A max 2N 12V 9 100T 10 100SLKTC 120TC 11 1L 4N 3L...

Страница 12: ...x2 x2 3 13b 13a 12b 12a 100T 100SLKTC 120TC 100T 100SLKTC 120TC...

Страница 13: ...x4 14a 13c 100SLKTC 120TC 100T 15 14b...

Страница 14: ...1L 2N 3L 4N 220 240V 50HZ 12V AC 16 100SLKTC 120TC 120TC 100SLKTC 10 17 100SLKTC 120TC...

Страница 15: ...18...

Страница 16: ...es de contacts et les accessoires rendez vous sur www manrose com Wi cej informacji na temat gwarancji danych kontaktowych oraz wyposa enia mo na znale na stronie www manrose com Para obtener informac...

Отзывы: