Electrical Service
n
Warning
All wiring must conform to local, state and national codes.
Voltage/Phase
Electrical Rating
230/50/1
0.6 kW
230/60/1
0.6 kW
115/60/1
0.6 kW
VOLTAGE
The maximum allowable voltage variation is ±10% of the
rated voltage on the ice machine model/serial number plate
at start-up (when the electrical load is highest).
n
Warning
The ice machine must be grounded in accordance with
national and local electrical codes.
n
Warning
Never use an extension cord. If an outlet is not within
reach of the ice machine’s power cord, have a proper
amperage outlet wired closer to the ice machine.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for each ice
machine.
NOTE: A disconnect means must be provided for field wiring.
ELECTRICAL RATIG
The electrical rating is used to help select the wire size of
the electrical supply. The wire size (or gauge) also depends
on location, materials used, length of run, etc., so it must be
determined by a qualified electrician.