Manitowoc QM-100 Скачать руководство пользователя страница 1

 

 

 

                                                 

  IMPORTANT 

                         WATER LEVEL CHECK INSTALLATION NOTICE 

                                           

Q-0130, Q-0210, Q-0270, QM-45, QM-100 

 

Water Level Check 

 
The water float valve setting may change during shipping.  Verify the water level is correct at initial startup. 
Check the water level while the ice machine is in the freeze cycle and the water pump is running.  The 
correct water level is 3/8

 (9.5mm) to 1/2" (12.7mm) below the top of the standpipe.  A black line is present 

to indicate the correct level.  The water level is set correctly when water is slightly below or contacts the 
black line during the freeze cycle.  Use the following procedure to check the water level: 

 

 

 

 

 

 

 

 

 

Correct Water Level  

 

1.

 

Verify the ice machine is level. 

2.

 

Remove the siphon cap from the standpipe. 

3.

 

Place the main ON/OFF/WASH toggle switch to the ON position  and wait until the float valve stops 
adding water.  

4.

 

Observe the water level: 

 

If the water level is correct, continue with step 5. 

 

If the water level is incorrect,  bend the float stem until the water level contacts or is slightly 
below the black line (3/8

 to 1/2" [9.5mm to 12.7mm] below the standpipe).  

5.

 

Move the main ON/OFF/WASH toggle switch to the OFF position.  The water level in the trough will 
rise above the standpipe and run down the drain. 

6.

 

Replace the siphon cap on the standpipe and verify the water level and siphon action by repeating steps 3 
through 5. 

 

 

 

 

Set water level 3/8” to 1/2

 

 (9.5 to 12.7 mm) below top of 

standpipe.  Water must be slightly 

below or contacting the line. 

Siphon Cap 

  1/2” (12.7mm) 

Standpipe 

3/8” (9.5mm) to 

   

Отзывы: