148
ICE MACHINE RUNS AND NO ICE IS PRODUCED
No water to ice machine
•
Correct water supply
Incorrect incoming water pressure
•
Water pressure must be 20-80 psi (1.4-5.5 bar)
Spray nozzle is blocked with mineral buildup
•
Clean and sanitize the ice machine
Ambient temperature is too high or low
•
Ambient temperature must be between 50°F and
110°F (10°C and 43°C)
Thermistor Disconnected or Open
•
Refer to thermistor diagnostics