Ice Machine Operation
Section 3
Operational Checks
GENERAL
Your Manitowoc ice machine was factory-operated
and adjusted before shipment. Normally, a newly
installed ice machine does not require any
adjustment.
To ensure proper operation, always follow these
Operational Checks when starting the ice machine:
•
for the first time
•
after a prolonged out of service period
•
after cleaning and sanitizing
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
WATER LEVEL
The water level sensor is set to maintain the proper
water level above the water pump housing. The water
level is not adjustable.
If the water level is incorrect, check the water level
probe for damage (probe bent, etc.). Repair or replace
the probe as necessary.
Water Level Probe
ICE THICKNESS CHECK
The ice thickness probe is factory-set to maintain the
ice bridge thickness at 1/8” (3.2 mm).
NOTE: Make sure the water curtain is in place when
performing this check. It prevents water from
splashing out of the water trough.
1.
Inspect the bridge connecting the cubes. It should
be about 1/8” (3.2 mm) thick.
2.
If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase
bridge thickness, or counterclockwise to decrease
bridge thickness.
NOTE: Turning the adjustment 1/3 of a turn will
change the ice thickness about 1/16” (1.5 mm).
Ice Thickness Adjustment
Make sure the ice thickness probe wire and the
bracket do not restrict movement of the probe.
SV1208
1/8” (3.2MM)
ICE THICKNESS
ADJUSTING
SCREW
SV1707A
Содержание P Series
Страница 2: ...Part Number 80 1125 3 ...
Страница 4: ......
Страница 11: ...1 4 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 24: ...3 3 Section 3 Ice Machine Operation THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 27: ...3 6 Ice Machine Operation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...