222
Part Number 000014797 Rev02 05/18
U0140/UF0140 SELF-CONTAINED AIR-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10
70/21
90/32
70/21
10.2-11.7
12.4-14.1
13.0-14.8
1.0-2.5
80/27
11.2-12.8
13.0-14.8
14.6-16.5
90/32
11.8-13.4
14.6-16.5
17.6-19.9
100/38
14.6-16.5
17.6-19.9
19.9-17.6
110/43
16.5-18.7
19.9-17.6
20.3-23.0
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Condenser °F/°C
Water Temperature °F/°C
50/10
70/21
90/32
70/21
130
110
105
80/27
120
105
95
90/32
115
95
85
100/38
95
85
80
110/43
85
80
70
Based on average ice slab weight of 1.06 – 1.19 lb (481 – 540 g).
Regular cube derate is 7%
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10
200-250
55-18
135-170
75-110
70/21
200-250
60-20
140-170
75-120
80/27
220-265
65-22
145-190
75-120
90/32
240-315
70-24
165-200
75-120
100/38
300-380
80-30
200-235
75-120
110/43
310-400
90-32
210-240
75-120
Suction pressure drops gradually throughout the freeze cycle
Содержание NEO UD0140A
Страница 2: ......
Страница 20: ...20 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 182: ...182 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 215: ...Part Number 000014797 Rev02 05 18 215 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING Using Pinch Off Tool ...
Страница 252: ...252 Part Number 000014797 Rev02 05 18 ELECTRONIC CONTROL BOARD UDE065 1 2 3 4 5 6 ...
Страница 254: ...254 Part Number 000014797 Rev02 05 18 ELECTRONIC CONTROL BOARD UDE080 1 2 3 4 5 6 7 8 9 10 ...
Страница 258: ...258 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 259: ......