Hydraulic Systems
Cleanliness
Contaminants in a hydraulic system affect operation and will
result in serious damage to the system components. Dirty
hydraulic systems are a major cause of component failures.
Keep the System Clean
When removing components of a hydraulic system, cover all
openings on both the component and the crane.
If evidence of foreign particles is found in the hydraulic
system, flush the system.
Disassemble and assemble hydraulic components on a
clean surface.
Clean all metal parts in a nonflammable cleaning fluid. Then
lubricate all components to aid in assembly.
Sealing Elements
Inspect all sealing elements (O-ring, gaskets, etc.) when
disassembling and assembling the hydraulic system
components. Installation of new elements is always
recommended.
Hydraulic Lines
When installing metal tubes, tighten all bolts finger-tight.
Then, in order, tighten the bolts at the rigid end, the
adjustable end, and the mounting brackets. After tubes are
mounted, install the hoses. Connect both ends of the hose
with all bolts finger-tight. Position the hose so it does not rub
on the machine or another hose and has a minimum of
bending and twisting. Tighten both couplings.
Due to manufacturing methods there is a natural curvature to
a hydraulic hose. The hose should be installed so any bend
is with this curvature.
Visual Inspection of Hoses and Fittings
1.
Visually inspect hoses and fittings once a month or
every 250 hours for the following:
•
Leaks at hose fitting or in hose
•
Damaged, cut, or abraded cover
•
Exposed reinforcement
•
Kinked, crushed, flattened, or twisted hose
•
Hard, stiff, heat cracked, or charred hose
•
Blistered, soft, degraded, or loose cover
•
Cracked, damaged, or badly corroded fittings
•
Fitting slippage on hose
•
Other signs of significant deterioration
If any of the above conditions exist, evaluate hose
assemblies for correction or replacement. For replacement
of hose assemblies, refer to your Manitowoc Crane Care
Parts Manual.
DANGER
High Pressure/Temperature Hazard!
Exercise extreme care around pressurized hydraulic
systems. DO NOT work on a hydraulic system while it is in
operation or until all pressure is released.
Hydraulic oil is hot, it can cause severe burns.
Pressurized hydraulic oil can cause death or serious
injury.
Stay clear of all hydraulic oil leaks. Relieve system
pressure and use a piece of cardboard or paper to check
for leaks. Do not use your hands.
Fluid injected into skin must be surgically removed within
a few hours by a doctor familiar with this type of injury or
gangrene will result.
!
Содержание National Crane NBT30H-2
Страница 1: ...Service Manual National Crane NBT30H 2 ...
Страница 2: ......
Страница 40: ...1 30 03 20 2019 Control 613 06 INTRODUCTION NBT30H 2 SERVICE MANUAL ...
Страница 92: ...ELECTRIC SYSTEM NBT30H 2 SERVICE MANUAL 3 24 03 20 2019 Control 613 06 ...
Страница 110: ...BOOM MAINTENANCE NBT30H 2 SERVICE MANUAL 4 18 03 20 2019 Control 613 06 ...
Страница 132: ...SWING NBT30H 2 SERVICE MANUAL 6 14 03 20 2019 Control 613 06 ...
Страница 142: ...OUTRIGGERS NBT30H 2 SERVICE MANUAL 7 10 03 20 2019 Control 613 06 ...
Страница 158: ...LUBRICATION NBT30H 2 SERVICE MANUAL 8 16 03 20 2019 Control 613 06 ...
Страница 190: ...SCHEMATICS NBT30H 2 SERVICE MANUAL 10 2 ...
Страница 193: ......
Страница 194: ......