Installer Instructions
AMBIENT LOCATION REQUIREMENT
This equipment is rated for indoor use only. It will not
operate in sub-freezing temperature. In a situation
when temperatures drop below freezing, the
equipment must be turned off immediately and
properly winterized. Contact the manufacturer for
winterization process.
Electrical
GENERAL
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select
the wire size of the electrical supply. (Minimum circuit
ampacity is not the beverage/ice machine’s running
amp load.) The wire size (or gauge) is also dependent
upon location, materials used, length of run, etc., so it
must be determined by a qualified electrician. See
Specifications section.
!
Warning
All wiring must conform to local, state and
national codes.