149
Electrical
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select
the wire size of the electrical supply. (Minimum circuit
ampacity is not the beverage/ice machine’s running
amp load.) The wire size (or gauge) is also dependent
upon location, materials used, length of run, etc., so it
must be determined by a qualified electrician.
ELECTRICAL REQUIREMENTS
Refer to Ice Machine Model/Serial Plate for voltage/
amperage specifications.
SPECIFICATIONS
!
Warning
All wiring must conform to local, state and
national codes.
Model
Volt/Cycle/
Phase
Minimum
Circuit
Amps
Breaker Compressor
75
120/601
230/50/1
20.3
9.0
25A
16A
1/3 hp
.46 kW
150
120/601
230/50/1
21.5
10.7
30A
16A
12 hp
.97 kW
300
208-230/60/1
230/50/1
20.6
20.6
30A
25A
1 hp
1.9 kW
450
208-230/60/3
230/400/50/3
25.2
11.6
30A
20A
2.2 hp
2.0 kW