142
Carbonation System A or B
CARBONATOR SYSTEM
A OR B
YES /
END
NO
CARB MOTOR
DOES NOT
TURNON
CARB MOTOR
DOES NOT
TURNOFF
FIRSTVERIF
Y PRG
MODE 2 IS
SET TO “-
002”FOR
BOTH CARB
PUMPS
VERIFY NO “E1” ERRORGOTO
PROGRAM MODE 1 CONDUCTIVITY
“C000”
PRESS CARB A AND/OR CARB B
BUTTON, VERIFY CARB A AND/OR B
CONDUCTIVITY PROBES
NO
“CX__” X= A OR B
“CX00”
CARB
MOTOR
SHOULD BE
ON
“CX11”
CARB
MOTOR
SHOULD BE
OFF
YES /
END
VOLTAGE
AT ERC
AGIT
OUTPUT
TERMINALS
VOLTAGE
AT ERC
AGIT
OUTPUT
TERMINALS
NO
NO/
END
YES
YES
REPLACE ERC
CONTROL
BOARD
020001985
CHECK ALL WIRES
AND CONNECTORS
FOR OPEN ON CARB
TANK WIRING
HARNESSCHECK
CARB MOTOR
REPLACE ERC
CONTROL BOARD
020001985
STH13_Tech.book Page 142 Wednesday, September 15, 2010 3:20 PM