![Manitowoc MLC650 Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/manitowoc/mlc650/mlc650_service-maintenance-manual_701260049.webp)
Reference
Only
Manitowoc
Published 09-09-16, Control # 229-09
2-25
MLC650 SERVICE/MAINTENANCE MANUAL
HYDRAULIC SYSTEM
2
2
4.
Put the free end of a hose, with a quick drain coupler,
into a suitable container to catch the hydraulic oil. See
Section 9 in this manual for the hydraulic system
capacity.
5.
Verify the shut-off handle (1) is in the OPEN position.
6.
Screw the hose’s quick drain coupler onto the hydraulic
tank’s quick drain valve (4) and drain the tank
completely.
7.
Unscrew the hose’s quick drain coupler from the
hydraulic tank’s quick drain valve.
8.
Remove the access covers (3) from the tank.
NOTE:
Take care to prevent dust and wind-blown dirt from
entering the tank while the access covers are off.
9.
Clean out any sediment inside the tank.
10.
Carefully inspect the strainer (5) for damaged or clogged
holes and for sludge, gum, or lacquer formation. If
necessary, clean the strainer.
a.
Using a wrench, remove the strainer from inside the
tank.
b.
Soak the strainer in clean, nonflammable solvent.
Brush off the outer surface of the strainer and flush it
from the inside out. Discard the strainer if it is
damaged.
c.
Securely reinstall the strainer.
11.
Using new seals, securely fasten the access covers to
the tank.
12.
Replace the desiccant breather cartridge. See
Replacing the Desiccant Breather Cartridge on page 2-
22
13.
Replace the three return filter elements. See
the Return Filters on page 2-23
.
14.
Fill the tank through the power fill coupling (6) or manual
fill port (7) to the Full Cold Level while watching hydraulic
tank display on the information screen. Use the proper
hydraulic oil. See Section 9 in this manual for hydraulic
oil information.
NOTE:
Do not fill the tank to 100%. Oil will flow out of the
breather.
15.
Close the air vent valve.
16.
Start the engine and allow the hydraulic system to rise to
normal operating temperature.
17.
Check for leaks and correct them as required.
18.
Stop the engine.
19.
Check the tank level, and fill as required.
NOTE:
If the hydraulic system was extremely dirty (gum or
lacquer formation on parts indicated by erratic,
jerky, or sluggish operation) repeat this Changing
the Hydraulic Oil procedure after 48 hours of
operation.
Servicing the Pumps
for the following procedure.
It is not necessary to drain the hydraulic tank when servicing
the hydraulic pumps. To service the pumps, move the
hydraulic tank supply shut-off valve (1a) to the CLOSED
position.
Move the hydraulic tank supply shut-off valve (1b) to the
OPEN position after servicing the pumps and before starting
the engine.
CAUTION
Contamination Hazard!
Do not fill the hydraulic tank through the breather opening
or through the top of the return filter(s). Harmful
contaminants will enter the hydraulic system. Damage to
pumps and motors can occur.
CAUTION
Avoid Damage to Pumps!
Open the hydraulic tank shut-off valve before starting the
engine. Failing to perform this step will result in damage to
the pumps from cavitation.
Содержание MLC650
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc MLC650 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 375: ...R e f e r e n c e O n l y ...
Страница 376: ...R e f e r e n c e O n l y ...