![Manitowoc MLC150-1 Скачать руководство пользователя страница 93](http://html.mh-extra.com/html/manitowoc/mlc150-1/mlc150-1_service-maintenance-manual_701242093.webp)
Manitowoc
Published 03-21-2021, Control # 264-01
4-9
MLC150-1 SERVICE/MAINTENANCE MANUAL
BOOM
4
PHYSICAL BOOM STOP
See
Figure 4-5
Physical Boom Stop Angles
Physical boom stops (2) serve the following purposes:
•
Assist in stopping the boom smoothly at any angle
above 59.1°
•
Assist in preventing the boom rigging from pulling the
boom back when traveling or setting loads with the
boom at any angle above 59.1°
•
Assist in moving the boom forward when lowering the
boom from any angle above 59.1°
•
Provide a physical stop at 89.9°
Physical Boom Stop Operation
•
When the boom is raised to 59.1°, the springs start to
compress (View A).
•
As the boom is raised higher, spring compression
increases to exert greater force against the boom.
•
If for any reason the boom is raised to 89.9°, the springs
fully compress to provide a physical stop (View B).
Physical Boom Stop Adjustment
The physical boom stops do not require adjustment.
LATTICE SECTION INSPECTION AND
LACING REPLACEMENT
Refer to Folio 1316 at the end of this section for lattice
section inspection and lacing replacement instructions.
WARNING
Collapsing Boom Hazard!
Physical boom stops must be installed for all crane
operations.
Physical boom stops do not automatically stop boom at
maximum operating angle.
Automatic boom stop must be installed and properly
adjusted.
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...