![Manitowoc MLC150-1 Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/manitowoc/mlc150-1/mlc150-1_service-maintenance-manual_701242091.webp)
Manitowoc
Published 03-21-2021, Control # 264-01
4-7
MLC150-1 SERVICE/MAINTENANCE MANUAL
BOOM
4
Automatic Boom Stop Adjustment — with
Luffing Jib
Unless other wise indicated, refer to View A,
for
the following procedure.
The limit switch (10) is disabled by the control system when
the RCL/RCI is configured for boom with luffing jib.
The limit switch (11) for the automatic boom stop with boom
and luffing jib was set at the factory and should not require
periodic adjustment. Adjustment is necessary when:
•
Parts are replaced
•
The wrong angle is displayed in the RCL/RCI
The following instructions assume that the RCL/RCI is
installed and properly calibrated.
During the following procedure, the boom angle is monitored
on the Working Screen of the RCL/RCI Display (
) and on a smart level (4, View B,
1.
Park the crane on a firm level surface or level the crane
by blocking under the crawlers.
2.
Slowly raise the boom while monitoring the boom angle
on the RCL/RCI working screen.
3.
The boom must stop at 88.5°.
4.
If the boom does not stop at the specified angle, proceed
as follows:
a.
Remove the cover from the boom stop assembly.
b.
Lower the boom to approximately 80°.
c.
Loosen the jam nuts (7), the adjusting screws (6),
and the mounting screws (8).
d.
Slide the limit switch (11) rearward approximately
52,4 mm (1 in).
e.
Raise the boom to 88.5° and verify the boom angle
with an accurate smart level (4, View B) placed on
the boom butt bottom chord. The smart level angle
should read angle
X2
.
f.
Slide the limit switch (11) forward in the mounting
slots until the roller (9) is contacting the sloped edge
of the actuator rod (5).
g.
Turn the rear adjusting screw (6) clockwise to move
the limit switch forward in the mounting slots
only
enough to click the limit switch open and stop
.
h.
Securely tighten the mounting screws (8), both
adjusting screws (6) against the limit switch (11),
and the jam nuts (7).
i.
Boom down and then boom back up. The boom
must stop at the 88.5° maximum boom angle.
j.
If necessary, loosen the jam nuts (7) and the
mounting screws (8) and fine tune the adjustment
using the adjusting screws (6).
k.
When done, securely tighten the mounting screws
(8), both adjusting screws (6) against the limit switch
(11), and the jam nuts (7).
l.
Reinstall the cover on the boom stop assembly.
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...