2
9.
Discard the hydraulic oil according to local
environmental regulations.
10.
Remove the access covers (19) from the hydraulic tank.
Take care to prevent dust and wind-blown dirt from
entering the tank while the access covers are off.
11.
Clean out any sediment from inside the hydraulic tank.
12.
Service the suction strainer if needed (see
13.
Replace the filter elements (see
).
14.
Replace the breather (see
).
15.
Using a new seal, securely fasten the access covers to
the hydraulic tank.
16.
Remove the quick-drain drainer assembly and attach
the dust cap to the quick-drain valve.
17.
Check that all pump and motor cases are filled with fresh
oil filtered through an owner-supplied 10-micron filter.
18.
Fill the hydraulic tank to the Full Cold Level mark on the
oil level sight gauge (3). Use the proper hydraulic oil
listed in the Lubrication Guide.
Fill the tank through the fill plug (7) opening. Filter the oil
through an owner-supplied 10-micron filter.
19.
Close the Schrader valve (3) and the vent valve (4).
20.
Start the engine and allow the hydraulic system to reach
its normal operating temperature.
21.
Check for leaks and correct them as required.
22.
Stop the engine.
23.
Check the hydraulic tank level and fill as required.
NOTE:
If the hydraulic system was extremely dirty (gum or
lacquer formation on parts indicated by erratic,
jerky, or sluggish operation), repeat the procedure
after 48 hours of operation.
Servicing Pumps
It is not necessary to drain the hydraulic tank when servicing
the hydraulic pumps. To service the pumps, close the
hydraulic tank shut-off valves (17,
CAUTION
Contamination Hazard!
Do not fill the hydraulic tank through the breather opening.
Harmful contaminants will enter the hydraulic system.
Damage to pumps and motors can occur.
FIGURE 2-22
1
Quick-Drain Drainer
2
Clamp
3
Hose
CAUTION
Avoid Damage to Pumps!
Open the hydraulic tank shut-off valves before starting the
engine. Failing to perform this step will result in damage to
the pumps from cavitation.
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...