![Manitowoc MLC150-1 Скачать руководство пользователя страница 168](http://html.mh-extra.com/html/manitowoc/mlc150-1/mlc150-1_service-maintenance-manual_701242168.webp)
POWER TRAIN
MLC150-1 SERVICE/MAINTENANCE MANUAL
7-8
Published 03-21-2021, Control # 264-01
ENGINE COOLING SYSTEM
Checking Coolant Level
Daily (at start of shift) or Every 8 Hours of Engine
Operation (whichever occurs first) — when coolant is
cold
For service other than checking the coolant level, refer to
Cummins’ literature/online site for detailed instructions.
See
Figure 7-7
.
1.
Stop the engine and lockout-tagout the ignition switch.
2.
Unlock and open the access door (2).
3.
The coolant must be at the middle of the sight gauge (3).
Add coolant if necessary.
4.
To prevent engine damage, stop the engine and wait
until the coolant temperature is below 50°C (122°F).
5.
Take care to prevent being burned by hot coolant as
follows.
a.
Place a heavy cloth over the fill cap (4).
b.
Turn the fill cap counterclockwise until the pressure
starts to release (indicated by a hissing sound).
c.
Wait for the pressure to escape completely.
d.
Turn the fill cap fully counterclockwise and remove
it.
6.
Slowly add a 50/50 coolant mixture of water and
ethylene glycol until the coolant is at the middle of the
sight gauge (3).
7.
Securely install the fill cap (4).
8.
Close and lock the access door (2).
Changing Coolant
Every Other Year or Every 2000 Hours of Engine
Operation (whichever occurs first)
See
Figure 7-7
.
Draining
1.
Stop the engine and the ignition switch.
2.
Attach a drain hose to the drain valve (5). Place the
other end of the drain hose into a suitable container that
FIGURE 7-7
Item Description
1
Radiator
2
Lockable Access Door
1
Sight Gauge
2
Fill Cap—1.03 bar (15 PSI)
3
Drain Valve
WARNING
Burn Hazard!
Hot and pressurized coolant can burn, causing serious
injury. Do not remove the coolant fill cap while the coolant
is hot. Wait for it to cool to below 50°C (120°F).
Material Hazard!
Coolant is toxic. Do not ingest. Dispose of in accordance
with all local and other applicable environmental
regulations.
REFERENCE
ONLY
Содержание MLC150-1
Страница 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Страница 2: ...R E F E R E N C E O N L Y ...
Страница 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Страница 98: ...MLC150 1 SERVICE MAINTENANCE MANUAL 5 iv Published 03 21 2021 Control 264 01 R E F E R E N C E O N L Y ...
Страница 205: ...R E F E R E N C E O N L Y ...
Страница 206: ...R E F E R E N C E O N L Y ...