COMPRESSOR REPLACEMENT
I1406 SERIES
9. Insert the NEW compressor into the Ice Machine, and
Position the compressor as shown.
11. Purge the system with nitrogen before and during
all brazing operations.
I1406 Air, Water, & Remote Ice Machines
12. Position the tubes back into compressor.
13. Replace the filter drier before evacuating the refrigeration
system of the ice machine.
Secure in place while brazing the joints
10. Reinsert the old tubing into the new compressor ports.
Braze all tubing into place
.
Insert 1/2 OD discharge tube into the discharge port of 14. Evacuate to 500 microns minimum.
the compressor. Insert 5/8 OD suction tube and bushing Insure that all the tubing is not rubbing against
supplied with the kit, (if required) port of the compressor. anything in the ice machine.
Braze tubes into the compressor ports.
Insure that the thermistor and clip are replaced back onto
the 1/2 OD discharge tube and the new thermistor boot
Adjust the tubing to fit without rubbing
supplied in the kit.
any other tubing or parts of the ice machine.
15. Reinstall the corner post and then the top rail.
16. Be sure to replace the run capacitor supplied with
compressor kit.
17. Weigh in correct refrigerant charge from the nameplate
found on the ice machine.
18. Reconnect the compressor with the wiring harness.
19. Reinstall all the other remaining outer panels.
20. Reconnect the power and turn on power switch.
Test and run the ice machine.
Suction tube
position.
New
Compressor
Discharge tube
connection position
Suction
Tube
Discharge
Tube
Thermistor boot