2-4
Published 01-14-2021 Control # 707-01
HYDRAULIC SYSTEM
TMS9000-2 SERVICE MANUAL
Maintenance
Hydraulic Oil Recommendations
For the hydraulic oil specifications, refer to
Draining and Flushing
If a component has been changed because of a failure that
might allow metal or abrasive particles to enter the system,
all systems must be thoroughly checked, drained, and
flushed.
1.
Remove the reservoir drain plug. Allow about three
minutes after hydraulic oil stops flowing from the drain
port for the side walls to drain.
2.
Clean and install the reservoir plug and fill the reservoir
with a 50/50 mixture of fuel oil and clean hydraulic oil.
FIGURE 2-2