![Manitowoc Grove GRT9165 Скачать руководство пользователя страница 210](http://html.mh-extra.com/html/manitowoc/grove-grt9165/grove-grt9165_service-manual_701207210.webp)
POWER TRAIN
GRT9165 SERVICE MANUAL
7-30
Published 10-01-2020 Control # 699-00
Table 7-2Troubleshooting
SYMPTOM
PROBABLE CAUSE
REMEDY
1.
Low clutch pressure.
a.
Low oil level.
a.
Fill to proper level.
b.
Clutch pressure regulating
valve spool stuck open.
b.
Clean valve spool and housing.
c.
Faulty charging pump.
c.
Replace pump.
d.
Broken or worn clutch shaft or
piston sealing rings.
d.
Replace clutch shaft or sealing
rings, as applicable.
e.
Clutch piston bleed valve stuck
open.
e.
Clean bleed valves thoroughly.
2.
Low converter charging pump
pressure.
a.
Low oil level.
a.
Fill to proper level. Refer to
b.
Suction screen plugged.
b.
Clean suction screen.
c.
Defective oil pump.
c.
Replace pump.
3.
Overheating.
a.
Worn oil sealing rings.
a.
Remove, disassemble, and
rebuild converter assembly.
b.
Worn oil pump.
b.
Replace pump.
c.
Low oil level.
c.
Fill to proper level.
4.
Noisy converter.
a.
Worn oil pump.
a.
Replace pump.
b.
Worn or damaged bearings.
b.
A complete disassembly will be
necessary to determine what
bearing is faulty.
5.
Lack of power.
a.
Low engine RPM at converter
stall.
a.
Tune engine and check
governor.
b.
See “Overheating” and make
same checks.
b.
Make corrections as explained
in “Overheating.”
Содержание Grove GRT9165
Страница 1: ...Service Manual Grove GRT9165 9897 ...
Страница 4: ...THIS PAGE BLANK ...
Страница 112: ...HYDRAULIC SYSTEM GRT9165 SERVICE MANUAL 2 70 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 138: ...ELECTRICAL SYSTEM GRT9165 SERVICE MANUAL 3 26 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 296: ...MAINTENANCE AND LUBRICATION GRT9165 SERVICE MANUAL 9 52 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 301: ......
Страница 302: ......