POWER TRAIN
999 SERVICE/MAINTENANCE MANUAL
7-6
Published 05-16-17, Control # 233-03
AIR CLEANER
See
for the following procedures.
The air cleaner filters (12 and 13) require periodic
maintenance.
•
Clogged air cleaner filters will prevent adequate air flow
to the engine, causing poor starting and increased
exhaust emissions.
•
An improperly installed or damaged air cleaner can
allow dirty air to be drawn directly into the engine.
Either condition can cause engine damage.
Inspection
To maintain engine protection and filter service life, inspect
the filters at the specified intervals:
FIGURE 7-5
Item
Description
1
Service Indicator
2
Reset Button
3
Air Cleaner Housing
4
Pre-Cleaner
5
Service Cover
6
Clamp (7-1/4 in)
7
Rubber Elbow
8
Clamp (5-1/2 in)
9
Steel Tube
10
Rubber Reducing Elbow
11
Clamp (4-1/2 in)
12
Primary Filter (2)
13
Secondary Filter
11
12
12
M100669
M100770
M100771
3
13
11
13
1
M100786
2
3
5
4
6
7
8
9
8
10
11
Access Ladder on Right
Side of Crane
Содержание 999
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 999 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 173: ...R e f e r e n c e O n l y Manitowoc Published 05 16 17 Control 233 03 4 19 999 SERVICE MAINTENANCE MANUAL BOOM 4 ...
Страница 174: ...R e f e r e n c e O n l y BOOM 999 SERVICE MAINTENANCE MANUAL 4 20 Published 05 16 17 Control 233 03 ...
Страница 297: ...R e f e r e n c e O n l y ...
Страница 298: ...R e f e r e n c e O n l y ...