7.3 Setting up the energy supply
1.
Release the locking mechanisms of the service access door
with the ignition key and unlock with the lever.
2.
Open service access door with the handle.
ð
L
WARNING! Danger of falling.
–
Carefully open service access door.
The service access door opens by means of a gas
spring. The operator may be pushed off the walkway
by the opening service access door and be injured.
The service access door opens.
Press the battery disconnect switch.
ð
The battery disconnect switch lights up.
1.
Close the service door.
2.
Engage the locking mechanisms of the service access door
with the lever and lock with the ignition key.
Lights up
Flashes (approximately
10 minutes)
Off
The electrical system of
the machine is connected
to the battery.
The disconnection of the
machine's electrical
system from the battery is
prepared.
The engine operating data
are saved.
The DEF in the lines is
pumped into the tank.
The electrical system of
the machine is discon-
nected from the battery.
Open the service access door.
Switching on the battery discon-
nect switch
Closing the service access door
Battery disconnect switch
Operation
27.04.2020
140.5.204 Telescopic crane
412
Fo
r
Reference
Only
Содержание 140.5.204
Страница 69: ...Safety instructions 27 04 2020 140 5 204 Telescopic crane 69 F o r R e f e r e n c e O n l y ...
Страница 70: ...Safety instructions 27 04 2020 140 5 204 Telescopic crane 70 F o r R e f e r e n c e O n l y ...
Страница 87: ...Safety instructions 27 04 2020 140 5 204 Telescopic crane 87 F o r R e f e r e n c e O n l y ...
Страница 88: ...Safety instructions 27 04 2020 140 5 204 Telescopic crane 88 F o r R e f e r e n c e O n l y ...