TECHNICAL DATA
Oxygen Analyzer Series PMA
®
Version PMA 45K1
heated oxygen analyzer in aluminium cast hous-
ing
Part-No.
05A4060
:
PMA 45 K1,
power supply 230 V 50 Hz
05A4060a
:
PMA 45 K1,
power supply 115 V 60 Hz
Measuring ranges
2 measuring ranges selectable internally: 0-1, 0-2,5, 0-5, 0-10 and 0-
25 vol% O
2
linear and position EXTERN
Remote identification of measuring
range
Potential free contacts for each selected measuring range, capacity
max. 24 V DC, 0.5 A
Combined analogue/digital indication Digital indication LCD 4
1
/
2
digit, 9 mm high for measuring range 0-
100 % O
2
, selectivity 0.01% O
2
Measuring range remote change-over Measuring ranges selectable via external potential-free contacts
30 V DC 3 mA DC
Output signal
0-10 V DC, electrically isolated, load > 100 K
Ω
for 100 vol% measur-
ing range and 0-20 or 4-20 mA
*
for selected range, electrically isolat-
ed, max. Load 300/500
Ω
Status alarm
For minimum flow alarm, transmitter temperature < 40 °C, light source
defective, measuring system defective, failure of tension: LED-
indication and contact outlet: change-over contact, potential-free, max.
24 V DC, 0.5 A
Response time for 90% value
< 5 seconds at 60 Nl/h air
Accuracy after calibration
Deviation: analogue signal output = ±1 % of span 2.5 – 25 % / Digital
indication = ±0.1 vol% O
2
, = ±2 % of span 1%
Reproducibility
Analogue output = < 1 % of span /
Digital indication = ± 0.1 vol% O
2
Influence of ambient temperature
No influence up to 50°C
Influence of barometric or outlet pres-
sure
The O
2
indication varies proportionally to the barometric or outlet
pressure
Influence of the sample gas quantity Variation between 0-60Nl/h air will cause a change of indication
<0.2 vol% O
2
Sample gas quantity
Max. 60 Nl/h
Flow alarm
Thermal conductivity sensor in measuring cell outlet
Pressure resistance
Operating pressure max. 0.6 bar, accident resistance max. 16 bar
Density
Leak rate < 10
-6
mbar x l/s with He leak test
Gas volume of the sample gas way
ca. 12 ml
Sample gas temperature
-10 °C up to +50 °C dry gas
O
2
Transmitter temperature
Adjusted at works to 55 °C
Ambient temperature
-10 °C up to +50°C
Storage temperature
-20 °C up to +60 °C, relative humidity 0-90% rF
Power supply
Internal power supply unit available for 230VAC standard or 115 V AC
(a)*
±10 %, 40-60 Hz, 35.5 VA
Electrical connections
Clamps 2.5 mm
2
, 4 x M20 cable gland ø11-13.5 mm (power supply,
signals, span position and remote selection, status alarm)
Material of parts in contact with sam-
ple gas
Platinum, glass, stainless Steel 1.4571, Epoxy
Sample gas connections
1/4“ NPT i
Protection
IP 54 EN 60529
Applied standards
Electrical safety EN 61010 part 1 8.2002
EMC: Interference emission EN 61000 part 6-3:2007 and EN 61000-6-
4:2007, Interference resistance EN 61000 part 6-2:2006
Housing / Colour
Alu cast housing for wall mounting / blue
Dimensions / Weight
356 x 275 x 200 mm / h x w x d / approx. 20 kg
OPTIONS EN
for exchange of outdat-
ed instruments
1.:
2 connecting pipes 1/8“, 500 mm long and 2 tube fittings –
straight connection
2.:
Adaption mounting plate with fastening material
*
Please specify with your order.