Ref.: MEL-WA(3D HCV) - OM Ver.1.7
124
8. MAINTENANCE
The equipment requires only minor maintenance to keep the equipment operating properly.
We recommend attention to the following points for getting maximum benefit out of the
equipment.
1.
Keep the area around the Aligner clean. Remove any tools or other items that are leaning
against the Aligner.
2.
Use only recommended Accessories / Spares. Accessories from other manufacturer may
not fit or function properly and may damage the equipment.
3.
For continuous protection against fire hazard replace the Control fuses only with same
type and rating of CE marked Fuse.
Control fuse F1
–
3A, Dia 5 mm x 20 mm, Slow blow type Glass fuse
Control fuse F2
–
5A, Dia 5 mm x 20 mm, Slow blow type Glass fuse
4.
Protect the System from direct sunlight.
5.
Do not attempt to open the System cabinet or Interface box for any reason as you may
spoil the Electronic circuit and components. In case of any fault, please call Service
Engineer.
6.
Protect the Rotary plates from dust. Foreign particles / dust may affect the rotation,
leading to wrong Caster / Kingpin readings. Service the Rotary plates once in 3 months.
7.
Clean the Wheel Brackets periodically and lubricate for smooth functioning. Also Clean
the Screw rod and guide shafts with oil.
8.
Target plate is a sensitive reflecting surface to reflect the IR light to the Camera received
from the IR source. Therefore, it is the responsibility of User to keep the Target plate clean
and free from dust & scratches.
The following tips will help the end user to maintain the Target plates in good condition.
Improper usage will damage the target plate permanently.
DO NOT touch the reflecting surface of the Target plate with dirty (Oil /Grease)
hands.
Handle the Target plates along with the Wheel brackets only. DO NOT detach the
plates from the Wheel bracket.
Hold only the outer frame of Target plate while leveling the spirit bubble.
Clean the Target plates using compressed air to remove dust particles and then
wipe the surface of the plate with soft cloth. Clean the reflecting surface with the
help of cleaning agent (Glass cleaner/ Colin) weekly once, using micro fiber cloth
(soft cloth).
Caution:
Never use Acid / Thinner / Detergent based cleaning agent.
Cover the Target plates using dust cover when not in use to prevent foreign particles
settling on it.
DO NOT drop the Target plates.
DO NOT make any identification mark (Shop name, bay name etc.) on the reflecting
surface.
Store the Target plates in closed area (DO NOT expose it to sunlight) when not in
use.
To increase the life of Target plate, a scratch guard (used in Mobile phones /
Laptops) can be pasted on the front surface.
DO NOT soak the Plate in rain / snow.
DO NOT store the Target plates near any heat emitting equipments.
Do not interchange the Target plate from front to rear or vice versa.
9.
Keep the System covered when not in use to avoid dust.
10. Keep the System away from Moisture.