Ref.: 3DWA - SM Ver.1.8
26
1
2
3
4
5
6
7
8
9
10
4.1.5.
PC ACCESSORIES COLUMN (For In-Lift model)
1.
Fix the Monitor stand (1), CPU tray (2),
Keyboard tray (3) & Printer tray (4) with the
Accessories Column as shown:
NOTE: Interface box (5) will be fixed with the
Accessories column at Factory itself
2.
Place the assembled PC accessories column at
the right side of the lift to facilitate alignment of
Right hand steering drive vehicles. In case of
left hand steering drive, place the column at left
side.
3.
Fix column using Anchor bolt in its location after
calibration of left & right camera vertical column
on lift.
NOTE: Excessive pounding will deform the
Anchor bolts & make future service difficult
Fig. 21
4.2.
FOUNDATION
4.2.1.
VERTICAL COLUMN
(Applicable only for PT / VH / AVH models)
1.
Draw a centre line centre (geometric centre line) to the alignment pit/lift.
2.
Make a mark at 2mtr from the Left and Right Rotary plates centre. Place
the Vertical column centre on the centre line to the alignment pit/Lift
along the 2mtr line.
For DT model, place the Accessories mounting Vertical column at the
geometric centre line 2000mm from the Rotary plate centre.
3.
Place the Horizontal beam over the Vertical column bracket. Tighten the
bolt provided on the Horizontal beam. Use shims below the vertical
column base to level the Horizontal beam using water tube level.
For DT model, Place the Camera mounted Left & Right side Vertical
columns at the respective sides of the pit at the centre of marked
location (2000mm from Rotary plate centre & 1210mm from geometric
centre line). Ensure the floor levels where Camera mounted Vertical
columns are to be installed.
4.
Use two plumb near the Left and Right camera covers to create
horizontal beam reference point to measure the physical distance as
shown below:
PT model
GE
OM
ET
RIC
CE
NT
RE
LIN
E
860mm
860mm
WATER
LEVEL
1952mm
1952mm
Fig. 22
Содержание Fox 3D Smart Mobile PT
Страница 9: ...Ref 3DWA SM Ver 1 8 6 PIT DIMENSIONS Max Wheel base 3 2 4metre For VH model Fig 3...
Страница 16: ...Ref 3DWA SM Ver 1 8 13 FOUR POST LIFT DIMENSIONS Max Wheel base 4 metre For VH model Fig 10...
Страница 19: ...Ref 3DWA SM Ver 1 8 16 FOUR POST LIFT DIMENSIONS Max Wheel base 4metre For In Lift Fig 13...
Страница 25: ...Ref 3DWA SM Ver 1 8 22 VH model 12 3 7 8 9 4 5 2 1 10 11 11 13 14 Fig 15...
Страница 26: ...Ref 3DWA SM Ver 1 8 23 AVH model 12 3 7 8 9 4 5 2 1 11 13 14 6 Fig 16...
Страница 69: ...Ref 3DWA SM Ver 1 8 66 For Drive Through model Fig 118...
Страница 70: ...Ref 3DWA SM Ver 1 8 67 Fig 119...
Страница 72: ...Ref 3DWA SM Ver 1 8 69 For Drive Through model Fig 121...
Страница 73: ...Ref 3DWA SM Ver 1 8 70 For In Lift model 865 865 Fig 122...
Страница 92: ...Ref 3DWA SM Ver 1 8 89 10 DIAGRAMS 10 1 BLOCK DIAGRAM Fig 154...
Страница 93: ...Ref 3DWA SM Ver 1 8 90 10 2 WIRING DIAGRAM 10 2 1 PT VH MODEL Fig 155...
Страница 94: ...Ref 3DWA SM Ver 1 8 91 Fig 156...
Страница 95: ...Ref 3DWA SM Ver 1 8 92 10 2 2 AVH MODEL Fig 157...
Страница 96: ...Ref 3DWA SM Ver 1 8 93 Fig 158...
Страница 97: ...Ref 3DWA SM Ver 1 8 94 10 2 3 IN LIFT MODEL Fig 159...
Страница 98: ...Ref 3DWA SM Ver 1 8 95 Fig 160...