![Man D 0836 LE 401 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/man/d-0836-le-401/d-0836-le-401_operating-instructions-manual_4000919055.webp)
Commissioning and operation
55
Terminal box in the engine room / interface with light-emitting keys
The terminal box with light-emitting diodes functions at the same time as an engine room
monitoring panel.
If an alarm is issued, the corresponding light-emitting diode lights up. The following re-
lays are activated on the diagnosis unit:
D
Engine slow down (main alarm) = reduction of engine speed
D
Horn = acoustic alarm
D
Group alarm = collective fault indication
The keys are intended for:
D
Horn off
Switches off the alarm horn and the integrated buzzer
D
Flashing light off, transition to continuous light / test of light-emitting diodes
Switches off the flashing signal of the relevant warning lamp, i.e. the flashing
light switches to continuous light. Before the flashing signal is cleared, the
alarm horn must be switched off
D
Reset
Clears the alarm message (red warning lamp goes out)
Requirement for clearing an alarm message is:
−
Pressing the keys “Horn off” and “Test” in that order
−
Removing the cause of the alarm
−
In the case of an engine slow down alarm, short-term lowering of engine
speed below 800 rpm so that higher engine speed can be reached
−
In the case of a stop alarm, the alarm can only be deleted if the engine is at
a standstill
Содержание D 0836 LE 401
Страница 1: ......
Страница 2: ......
Страница 3: ...3 Operating Instructions MAN Marine Diesel Engines ...
Страница 4: ...4 ...
Страница 9: ...Declaracion 9 ...
Страница 17: ...Notes 17 ...
Страница 18: ...Commissioning and operation 18 Engine views D 0836 LE 401 11 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 ...
Страница 69: ...Notes 69 ...
Страница 75: ......
Страница 76: ......