Models TE-701 and TE-702
Duct Temperature Sensors
Technical Information
Rev. 0
7400 Flying Cloud Drive • Minneapolis, MN 55344-3720 • USA
800-843-5116 • 952-835-1626 • Fax 952-829-5331
www.mamacsys.com
IS.TE701/702-00
Ordering Information
Dimensions
Figure 1.
TE 701 A and B Dimensions
Figure 2.
TE 701 C and D Dimensions
Figure 3.
TE 702 A Dimensions
Figure 4.
TE 702 B and C Dimensions
Specifications
Platinum RTD Sensors
:
±
0.1% @ 32°F (0°C), Alpha: 385 per DIN
43760
Nickel RTD Sensors
: ±
0.5°F @ 70°F (21.1°C), 6,000 PPM/K T.C.R.
Balco RTD Sensors
: ±
0.5°F @ 70°F (21.1°C), 4,300 PPM/K T.C.R.
Thermistor Sensors
:
±
0.2°C interchangeability @ 77°F (25°C)
Operating Temperature
: -40°F to 250°F (-40°C to 125°C)
Probe Material
: 1/4-inch (6.3 mm) O.D., 0.5 mm wall
304 stainless steel
Flange Material
: 304 stainless steel
Bulkhead Fitting
: Brass with poly compression sleeve
Plastic Enclosure
: Polycarbonate, 30% glass filled, rated UL 94V-5-0
Steel NEMA-1/IP-30
: 18 Ga. galvanized steel
Steel NEMA-4/IP-65
: 18 Ga. cold-rolled steel, powder coated
Installation
Before Installation
• Read these instructions carefully. Failure to do so can result in
damage or electrical shock.
• Inspect packaging for signs of damage. If damaged, notify the carrier
immediately.
• Verify that the sensor specifications are suitable for the particular
application.
• Installers must be trained and qualified technicians.
•
Important
: All wiring must be compatible with applicable codes,
ordinances, and instructions.
Location
Install the sensor in a location where it will sample the average air
temperature in a duct. Avoid areas where the air is stratified because
these areas can cause sensing errors.
Mount the TE 701 A or B Sensor
1.
Drill a 3/8-inch (9 mm) hole into the duct or plenum where the
sensor will be installed.
2.
Insert the sensor probe into the duct or plenum until the flange rests
against the duct or plenum wall.
3.
Use the flange as a template to mark and drill holes for two #8 self-
tapping sheet metal screws (not provided).
4.
Fasten the sensor to the duct or plenum wall with the sheet metal
screws.
5.
Make the wiring connections. See Figure 5.
INSTALLATION
SENSOR
PROBE
LENGTH
701 A
701 B
701 C
701 D
Flange mount,
3-inch lead wire
Flange mount,
6-foot cable
Bulkhead fitting,
3-inch lead wire
Bulkhead fitting,
6-foot cable
1
3
4
5
7
10
11
13
15
17
18
21
100-ohm platinum RTD
1,000-ohm platinum RTD
1,000-ohm nickel RTD
1,000-ohm Balco RTD
10,000-ohm NTC thermistor
3,000-ohm NTC thermistor
10,000-ohm NTC thermistor
5,000-ohm NTC thermistor
100,000-ohm NTC thermistor
20,000-ohm NTC thermistor
2,252-ohm NTC thermistor
1,800-ohm NTC thermistor
A
B
C
D
4 inches/
100 mm
6 inches/
150 mm
8 inches/
200 mm
12 inches/
300 mm
702 A
702 B
702 C
Polycarb plastic
enclosure IP-54
Galvanized steel
enclosure
NEMA-1/IP-30
Painted steel
enclosure
NEMA-4/IP-65
1
3
4
5
7
10
11
13
15
17
18
21
100-ohm platinum RTD
1,000-ohm platinum RTD
1,000-ohm nickel RTD
1,000-ohm Balco RTD
10,000-ohm NTC thermistor
3,000-ohm NTC thermistor
10,000-ohm NTC thermistor
5,000-ohm NTC thermistor
100,000-ohm NTC thermistor
20,000-ohm NTC thermistor
2,252-ohm NTC thermistor
1,800-ohm NTC thermistor
A
B
C
D
4 inches/
100 mm
6 inches/
150 mm
8 inches/
200 mm
12 inches/
300 mm