Part Number
Comments
Inspector Name
Date
Inspection:
Official periodic inspection must be made at least annually. The inspection must be performed by a
qualified person other than the intended user. If severe weather or conditions exist then inspections
must be carried out more frequently. All inspection results must be logged in the space provided above.
1. Make sure all labeling is affixed to the unit.
2. Inspect anchoring system for signs of damage or wear.
3. Record inspection results in the space provided above.
*If any damage that could affect the strength or operation of the device, or unsafe conditions are
found, proper disposal is required. The anchorage connector must be rendered unusable and then
properly discarded.
INSPECTION AND MAINTENANCE LOG
MAINTENANCE, CLEANING AND STORAGE
Cleaning periodically will prolong the life and proper functioning of the product. The frequency of
cleaning should be determined by inspection and by severity of the environment. Clean with com-
pressed air and/or a stiff brush using plain water or a mild soap and water solution. Do not use any
corrosive chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth and
hang to dry, or use compressed air. When not in use, store anchorage connector in a cool, dry, clean
environment, out of direct sunlight and free of corrosive or other degrading elements.
MODEL NUMBER:
DATE OF MANUFACTURE:
Содержание A6205
Страница 7: ...Notes...