1. Technical Specifications

Product type                                  Independent DALI sensor (Daylight harvest)

Operating voltage                           120~277VAC  50/60Hz

Switched power                              2 x 2000W (resistive)    2 x 800W (capacitive)

Power consumption                        < 1W

Detection angle                              360

o

Detection range                             10% / 50% / 100%

Hold time                                       2s / 30s / 1min / 5min / 10min  / 30min

Stand-by time                                0s / 10s / 1min  / 10min / 30min / + 

Stand-by dimming level                  10% / 20% / 30% 

Daylight threshold                          2 ~ 50Lux , Disable

Warmming-up time                        20s

Operating temperature                   -20

o

C ~ +50

o

C

IP rating                                        IP65    

8

3. Functions

Daylight sensor measures the available surrounding natural light, calculates how much electrical light is 
needed to reach the total lux expected. The demand is given to the LED driver by DALI signal, so as to 
deliver the needed amount of electric light.

3.1 Daylight Harvest (Daylight Regulating)

Sometimes also know as “Potential-Free” or “Volt-Free” sensor, the dry contact sensors from Hytronik are 
designed to operate with external monitoring systems. They operate as conventional occupancy sensors, with 
the output available as shown in the table below:

3.2 Dry Contact Control

Double “L” “N” terminal makes it easy for wire loop-in and loop-out, and saves the cost of terminal block and 
assembly time.

3.3 Loop-in and loop-out

HF Aisle Sensor with DALI Control 99 190 25

Installation and Instruction Manual 

2. Instruction and Dimension

Warnings: 

1. Installation of the sensor involves connecting it to the mains supply. This work must be 
    carried out by a specialist in accordance with electrotechnical regulations.
2. Disconnect supply before installing.

4. Wiring Diagram

5. Detection Pattern 

4

2

0

Light level

Time (hrs)

Normal Electric Light 

Daylight controlled light

Energy Saving Zone

Natural light

Hold time

Stand-by time

Wire out

Infrared remote receiver

Daylight sensor

Installation rack

Sensor Antenna

LED indication

1

2

5

.5

135

115.4

9

5

L

L

L

N

N

N

N

N

1

2

C

O

C

OM

+

1-10V+ DALI -

DALI

1-10V -

2

5

4

6

6

5

1

1

2

.9

5

0

.6

8

2

.3

114

56

Detection State

Contacts Made

Presence

Absence

Nc - Com

No - Com

LED Driver

LED Driver

99 190 25

Power

N

N

N

N

L

L

N

L

L

1

L

2

1-10V +
1-10V -

1-10V +
1-10V -

+

DALI -

DALI

+

DALI -

DALI

N

L

1-10V +
1-10V -

+

DALI -

DALI

N

N

C

O

C

OM

t

h

g

i

e

h

 

g

n

it

n

u

o

m

  

m

5

 

@

 

h

t

g

n

e

n

o

it

c

e

t

e

d

 

m

0

5

t

h

g

i

e

h

 

g

n

it

n

u

o

m

 

m

5

1

 

@

 

e

g

a

r

e

v

o

c

 

m

6

 

x

 

m

5

2

t

h

g

i

e

h

 

g

n

it

n

u

o

m

 

m

8

 

@

 

e

g

a

r

e

v

o

c

 

m

6

 

x

 

m

5

2

Varning!

Stäng av strömmen, ta ut säkringen på elcentralen eller ställ automatsäkringen till läge ”AV”, innan 
installationsarbetet påbörjas.
Skall installeras av behörig installatör och i enlighet med gällande föreskrifter.

www.malmbergs.com

2017.03.01

Art.no: 99 190 25