background image

814 SE 14TH AVENUE

PORTLAND OR 97214

USA

www.malekkoheavyindustry.com

Содержание DOWNER

Страница 1: ...814 SE 14TH AVENUE PORTLAND OR 97214 USA www malekkoheavyindustry com ...

Страница 2: ...TABLE OF CONTENTS DOWNER MANUAL V 1 BASIC OPERATION AND SAFETY 3 DESCRIPTION 4 OVERVIEW 5 EXPRESSION PEDAL AND CV ASSIGNMENT 6 REMOVING EXPRESSION OR CV ASSIGNMENT 7 WARRANTY 8 PG 2 ...

Страница 3: ...the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 7 Unplug this apparatus during lightning storms or when unused for long periods of time 8 No user serviceable parts inside Refer all servicing to qualified service person nel Servicing is required when the apparatus has been damaged in any way such as power s...

Страница 4: ... DOWN The High Pass and Low Pass filters allow for sculpting the perfect tone Add the ability to assign an expression pedal to your own combinations and settings within these features and in one sweep you can dial your tone from classic heavy fuzz to screaming experimental madness Features include Saturation or Wavefolding Control over Down function detune to full octave down Control over Down blen...

Страница 5: ...ctave BLEND Adds DOWN amount to output Set to max CW for 100 DOWN Set to max CCW for 0 DOWN OUTPUT JACK 1 4 mono out INPUT JACK 1 4 mono in 9vDC JACK Standard neg tip 2 5mm barrel connector EXPRESSION CV INPUT JACK Expresson pedal input for remote control of any combination of parameters Both positive or negative sweep can be assigned simultaneously CV input will also control all parameters PREAMP...

Страница 6: ...rol by changng the knob setting FOR INSTANCE Starting at 12 o clock setting the knob counterclockwise anticlockwise to 7 o clock will give you maximum positive sweep for that effect Or setting the knob clockwise to 2 o clock will give you less overall negative sweep range for that effect A SETTING EXAMPLE Hold down the stomp switch and turn the DOWN knob from a 12 o clock position counterclockwise...

Страница 7: ...e stomp down sweep the knob with the assigned setting all the way CCW then set to 12 o clock Release the stomp Now that parameter is no longer assigned to the EXP CV control and it is in manual mode NOTE Unplugging the EXP CV input will put the pedal in manual mode but the assignments remain until you zero them out ...

Страница 8: ...ranty does not cover any damage or malfunction caused by incorrect use such as but not limited to power cables connected backwards excessive voltage levels or exposure to extreme temperature or moisture levels The warranty covers replacement or repair as decided by Malekko Heavy Industry Please visit our website malekkoheavyindustry com to obtain full warranty information and to register your prod...

Отзывы: