background image

Содержание Deep Hunter

Страница 1: ......

Страница 2: ...orce during assembly and use Align the battery and carefully place it in its slot in the proper direction Do not force the battery in to the holder To obtain maximum performance do not expose battery...

Страница 3: ...Detection Mode 1 Interpreting Oscilloscope Data Mode 1 Eliminating Ferrous Metals Mode 1 Target Analysis Mode 1 Determination of Target Depth Mode 1 Recording and Examining The Records Usage With Mode...

Страница 4: ...t This coil is more effective in detecting single coins and smal ler objects All results of this system are monitored through an audio alert This coil can only be used in Mode 2 Mode 2 C32 Coil Coil C...

Страница 5: ...s are evaluated and presen ted to user on the large color LCD Display In addition the control box is equipped with an apparatus for easy handling Electronic System Unit Headphones Extension Shaft Conn...

Страница 6: ...eport in Mode 1 DEPTH This is the Control to switch to the Depth section in Mode 1 This is used for depth analysis 1 2 3 4 5 6 7 8 9 10 SENSITIVITY This is the Control used for adjusting the sensitivi...

Страница 7: ...y frequently needed to be used during searches This key enables clearing of erroneous signals and data and helps obtaining correct ones Frequent use of Reset key would eliminate erroneous incoming sig...

Страница 8: ...nadryplaceandatroomtemperature Batteriesshould be charged on a fire resistant surface The device should only be charged with the approved charger Overcharging or charging at the wrong voltage will sub...

Страница 9: ...o use headphones connect the headp hone cable to the headphone connection on the system box 5 After inserting the battery connect battery connection cable to the socket on the battery Close the cover...

Страница 10: ...7 USAGE Ensure that coil always remains parallel to the ground during searches RIGHT Failing to keep the coil in a position parallel to the ground may cause faulty results WRONG WRONG RIGHT...

Страница 11: ...8 USAGE CORRECT HOLD WRONG HOLD...

Страница 12: ...or detection of larger targets at significant depth Mode 1 function of the device can be used only with either the 36x44 cm coil or the 60x100 cm coil attached Manualresetisavailableinthispart sothere...

Страница 13: ...nce section after identifying the attached coil At the bottom of this section there is a part indicating the battery status The battery should be recharged as required By pressing and keys you will co...

Страница 14: ...for a productive search Therefore it is important that the user pay close attention to variances within the soil If you notice misleading signals are being detected by the device from chan ges in the...

Страница 15: ...ately 40 cm above the ground around your knee level at the original position and press the RESET button Note If you fail to raise the coil 40 cm above and begin by pressing the RESET no operation to b...

Страница 16: ...cm above the ground Repeat this process until the effect is completely removed until the signal on device disappears 8 40 cm 3 cm Reset If there is ground effect on device this effect will be seen on...

Страница 17: ...inta in the proper Ground Balance If you exceed these limits you will receive false signals 1 10 cm 10 cm The device will produce an audio signal when it detects metal or a cavity A signal will be pro...

Страница 18: ...ically depending on the depth of effect This will be shown on both the METAL and the PRECIOUS bars Metal effect can also be monitored in the graph located above the bars 4 If the target is a ferrous m...

Страница 19: ...time interpretation of the signals from the ground and the targets below If the target is two small pieces of metal and close to surface 2 If the target is two small pieces of metal and at a slightly...

Страница 20: ...require a readjustment of the Ground Balance for the ground in that specific area If the signal lines rise vertically and descend likewise there is no need to obtain the depth for this target The reas...

Страница 21: ...to save this report a message indicating the saving is completed will appear on the screen To exit this screen press OK or the RESET button If the user desires the device can be adjusted to eliminate...

Страница 22: ...get as reflected to the surface For this bring the coil towards the target by using the coil s side the front and rear parts of the coil are not used during this measurement 1 Target 2 To determine th...

Страница 23: ...ase the SCAN button after the signal disap pears 8 At the end of these processes a Depth Report showing the depth and measurement values entered will be obtained The value obtained is an approximate o...

Страница 24: ...records can be saved on the device Enter the Recording menu by pressing the RECORD key in the search mode Records can be reviewed by using the and the keys Press the OK button while viewing the recor...

Страница 25: ...and plowed soils soils containing high amounts of iron and places such as beaches etc As this key is turned from 1 towards 10 a loss of depth will be seen for some metals As this key is turned toward...

Страница 26: ...iron content or high levels of minerals contained within the ground It will not produce signals for ferrous metals however a reduction in metal detection depth will occur If you continue to receive si...

Страница 27: ...Beach Mineral and the Ferrous Adjustment to 10 If your search area has a highly variable structure adjusting Ground Balance at points where you receive the highest effects from the ground such as over...

Страница 28: ...in constant motion to enable the device to detect metals Since the device runs on an automatic reset principle if you keep the coil still over the target it will not detect the metal Target Target You...

Страница 29: ...1 85 Pounds 39x47 cm 15 x 18 5 1 200 gr 2 65 Pounds 85 135 cm 33 53 1 000 gr 2 2 Pounds T44 Coil Control Unit T100 Coil Optional C47Coil Optional Stem C32 Coil TECHNICAL SPECIFICATIONS Operating Syst...

Страница 30: ......

Отзывы: