background image

OWNERS MANUAL FOR

Oil Lubricated Air Compressor

MODEL No

MAC700

SPECIFICATION CHART

Model #

MAC700

Horsepower

2

SCFM @ 40 PSIG

3.8

SCFM @ 90 PSIG

3.3

Cut-In Pressure

100 PSI

Cut-Out Pressure

130 PSI

Bore

47 mm

Stroke

44 mm

Voltage -Single Phase

120

Motor RPM

1720

Amperage @ max pressure

12.4

Tank Size

2.6 Gallon

CSA/US Listed

Yes

Minimum Circuit Requirement: 15 AMPS

*A circuit breaker is preferred.  Use only a fuse or circuit
breaker that is the same rating as the branch circuit the air
compressor is operated on.  If the air compressor is connected
to a circuit protected by fuses, use time delay fuses.

IMPORTANT — Read the Safety Guidelines and ALL

instructions carefully before operating.

www.makitatools.com

Содержание MAC700

Страница 1: ...RPM 1720 Amperage max pressure 12 4 Tank Size 2 6 Gallon CSA US Listed Yes Minimum Circuit Requirement 15 AMPS A circuit breaker is preferred Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on If the air compressor is connected to a circuit protected by fuses use time delay fuses IMPORTANT Read the Safety Guidelines and ALL instructio...

Страница 2: ...DURES 9 Location Of the Air Compressor 9 Lubrication and Oil 9 Initial Start Up Procedure 10 Extension Cords 10 Piping 10 Grounding Instruction 10 OPERATING PROCEDURES 11 Daily Start up Checklist 11 MAINTENANCE 12 Filling with Oil 12 Changing the Oil 12 ROUTINE MAINTENANCE SCHEDULE 12 COLD WEATHER CONDITIONS 12 SERVICE INSTRUCTIONS 13 TROUBLESHOOTING GUIDE 14 FACTORY SERVICE CENTERS 17 WARRANTY 18...

Страница 3: ...s injury to you or others HOW TO PREVENT IT Review and understand all instructions and warnings in this manual Become familiar with the operation and controls of the air compressor Keep operating area clear of all persons pets and obstacles Keep children away from the air compressor at all times Do not operate the product when fatigued or under the influence of alcohol or drugs Stay alert at all t...

Страница 4: ...ould lead to a weakening of the tank and RESULT IN A VIOLENT TANK EXPLOSION RESULTING IN SERIOUS INJURY TO YOU OR OTHERS Failure to properly drain condensed water from the tank causing rust and thinning of the tank wall Modifications or attempted repairs to the tank Unauthorized modifications to the pressure switch safety valve or any other components which control tank pressure Exceeding the pres...

Страница 5: ...terials such as paint paint HOW TO PREVENT IT Any electrical wiring or repairs required to this product should be performed by qualified service personnel or a licensed electrician in accordance with national and local electrical codes Make certain that the electrical circuit to which the compressor is connected provides proper electrical grounding correct voltage and adequate fuse protection Neve...

Страница 6: ...serious injury Contact with hot parts such as the compressor head or outlet tubes could result in a serious skin burn HOW TO PREVENT IT Use an approved respirator designed for use with your specific application Always wear approved safety glasses with side shields when using the compressor Never point any nozzle or sprayer toward any part of the body or at other people or animals Always turn the c...

Страница 7: ...ur is considered misuse because the air compressor is undersized for the required air demand GENERAL INFORMATION This air compressor requires oil Now you can enjoy all the benefits of having an oil lubricated professional air compressor When oil is changed regularly it will give you long trouble free life Your air compressor can be used for operating paint spray guns air tools caulking guns grease...

Страница 8: ...nd to off to remove power when finished using the compressor or when compressor will be left unattended AIR INTAKE FILTER This filter is designed to clean air coming into the compressor pump This filter must always be clean and free from obstructions See Maintenance AIR COMPRESSOR PUMP To compress air the piston moves up and down in the cylinder On the down stroke air is drawn in through the air i...

Страница 9: ... When reducing from a higher to a lower setting first reduce to some pressure less than desired pressure Depending on the air requirements of each particular accessory the outlet regulated air pressure may have to be adjusted while you are operating the accessory INSTALLATION AND BREAK IN PROCEDURES LOCATION OF THE AIR COMPRESSOR Locate the air compressor in a clean dry and well ventilated area Th...

Страница 10: ...t will accept the plug on the air compressor Make sure the extension cord is in good condition Please see the chart below as the MINIMUM requirements Amp Length of Rating Cord in Feet 120 Volts 25 50 100 150 10 12 16 14 10 8 12 14 16 12 10 8 14 16 16 12 10 8 16 18 14 12 8 8 18 20 14 12 8 8 Piping Plastic or PVC pipe is not designed for use with compressed air Regardless of its indicated pressure r...

Страница 11: ...he regulator outlet pressure must never exceed the maximum pressure rating 3 Turn the pressure switch lever to ON AUTO and allow tank pressure to build Motor will stop when tank pressure reaches cut out pressure 4 Open the regulator by turning it clockwise Adjust the regulator to the correct pressure setting Your compressor is ready for use 5 Always operate the air compressor in well ventilated ar...

Страница 12: ... greater frequency of all maintenance checks ROUTINE MAINTENANCE SCHEDULE 1 Drain water from the air tank any moisture separators or transformers 2 Check for any unusual noise and or vibration 3 Manually check all safety valves to make sure they are operating properly 4 Inspect air filter replace if necessary 5 Inspect air lines and fittings for leaks correct as necessary Each year of operation or...

Страница 13: ...ir pressure from air tank and unplug outfit 2 Remove shroud 3 Loosen the top and bottom nut of the outlet tube and remove 4 Remove the pressure release tube and fitting 5 Unscrew the check valve turn counterclockwise using a socket wrench 6 Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper closed position The check valve may be cleaned wi...

Страница 14: ...ck If it does not move freely replace the valve Adjust or replace pressure switch Tighten fittings where air can be heard escaping Check fittings with a soap and water solution DO NOT OVER TIGHTEN A defective check valve results in a constant air leak at the pressure release valve where there is a pressure in the tank and the compressor is shut off Remove and clean or replace check valve DO NOT OV...

Страница 15: ...drop when the accessory is used adjust the regulator following the instructions Note Adjust the regulated pressure under flow conditions while accessory is being used Operate safety valve manually by pulling on ring If valve still leaks it should be replaced Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor yo...

Страница 16: ...zed Warranty Service Center for inspection or replacement if necessary Have checked at an Authorized Warranty Service Center Do not operate the compressor in the paint spray area See flammable vapor warning Have checked at an Authorized Warranty Service Center 1 Check fuse box for blown fuse and replace If necessary reset circuit breaker Do not use a fuse or circuit breaker with higher rating than...

Страница 17: ... 9876 Watson Road St Louis MO 63126 314 909 9889 NEBRASKA 4129 S 84th Street Omaha NE 68127 402 597 2925 NEVADA 3375 S Decatur Boulevard Suites 22 24 Las Vegas NV 89102 702 368 4277 NEW JERSEY 251 Herrod Boulevard Dayton NJ 08810 1539 609 655 1212 NEW YORK 4917 Genesee Street Cheektowaga NY 14225 716 685 9503 OREGON 828 19th Avenue N W Portland OR 97209 503 222 1823 PENNSYLVANIA 1904 Babcock Boule...

Страница 18: ...paid to one of Makita s Factory or Authorized Service Centers If inspection shows the trouble is caused by defective workmanship or material Makita will repair or at our option replace without charge This warranty does not apply where repairs have been made or attempted by others repairs are required because of normal wear and tear the tool has been abused misused or improperly maintained alterati...

Страница 19: ...9 MAIL THIS PORTION Your answers to the following questions are appreciated 1 This product was purchased from Home Center Other Hardware Lumber Store Tool Distributor Industrial Supply Construction Supply 2 Use of the product is intended for Construction Trade Industrial Maintenance Home Maintenance Hobby Other 5 Any comments 3 How did you learn about this product Magazine Radio From Dealer Exhibi...

Страница 20: ...Makita U S A Inc 14930 Northam Street La Mirada CA 90638 5753 First Class Postage Required Post Office will not deliver without proper postage ...

Отзывы: