Although  your  pN-106/112/224/236/248/260  is  neither  complicated  nor  difficult  to  operate,  we
recommend  you  take  a  few  minutes  to  read  this  brief  manual  and  familiarize  yourself  with  the  important
information regarding product features, setup and operation.

As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.

Installation

Environment

Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

1. read these instructions.
2. keep these instructions.

3. Heed all warnings.

4. follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. the wide

blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult

an electrician for replacement of the obsolete outlet.

10. protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11. only use attachments/accessories specified by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.

14. refer  all  servicing  to  qualified  service  personnel.  Servicing  is  required  when  the

apparatus  has  been  damaged  in  any  way,  such  as  power-supply  cord  or  plug  is

damaged,  liquid  has  been  spilled  or  objects  have  fallen  into  the  apparatus,  the

apparatus has been exposed to rain or moisture, does not operate normally, or has

been dropped.

S3125A

Features

Contents and Accessories

Contents and Accessories

1. AC power cord x 1EA
2. 3P Terminal Block x 1EA
3. 2P Terminal Block (AC Remote power) x 1EA
4. 8P Terminal Block x 1EA
5. Screw for Rack Mount x 4EA
6. Washer x 4EA
7. Operation manual x 1EA

Features

- HIGH-POWERED, HIGH-CAPACITY 1-CHANNEL CLASS-D POWER AMPLIFIER

High-Power,  high  performance  Class-D  Professional  Amplifier  has  up  to  240W/360W/480W/720W  1CH
power output.
* DPS-240S: 240W, DPS-360S: 360W, DPS-480S: 480W, DPS-720S: 720W

- EMERGENCY POWER BACK UP (DC 24V) CAPABILITY

the unit operates on a DC 24V battery power supply for emergency back up without UPS.

- SMPS (SWITCHING MODE POWER SUPPLY) POWER SCHEME

High efficient, light weight SMPS power system is utilized.

- RATED OUTPUT POWER VIA DC BACKUP SUPPLY

output power can be maintained as AC power when DC 24V power supplied.

- POWERFUL AND DETAILED SOUND QUALITY

High S/N ratio and low tHD reproduces powerful and detailed sound.

- COMPLETE PROTECTION CIRCUITS

Complete circuit protection is activated in case of amplifier overheating, output shorting, overload, over power
and DC output.

- OPERATION INDICATOR LED

leD display to check the operating status (AC, StBY, DC, PoWeR, SIg, -10dB, ClIP, PRt)

- BALANCED INPUT

this connection is used to ensure the lowest noise operation which eliminates the common noise from the cable.

- REMOTE POWER ON/OFF

the remote power allows the amplifier to be turned on or off from a distance or other device via dry contact
closure.

- PRIORITY INPUT

PgM is interrupted and over ridden by the Priority input, when a contact closure is received on the Priority input
terminal. this is Ideal for emergency message broadcasting applications.

Usermanual V1.1

Usermanual V1.1

Содержание DPS-240S

Страница 1: ...www majorcom fr DPS 240S 360S 480S 720S USER MANUAL Manual to download in PDF format on...

Страница 2: ...he power supply cord plug from the AC receptacle The mains plug of the power supply cord shall remain readily accessible CAUTION These servicing instructions are for use by qualified service personnel...

Страница 3: ...the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip ove...

Страница 4: ...switch is off StBY leD will turned on During operation of DC amplifier is keep going to work even if the switch of power is turned off 2 OUTPUT LEVEL INDICATOR 1CH 2CH 3CH 4CH Indicator display of un...

Страница 5: ...al this is Ideal for emergency message broadcasting applications Please refer to the following picture about the suitable cables PRIORITY VOLUME MIN MAX OUTPUT VOLTAGE 70V 100V AC POWER REMOTE N C CH...

Страница 6: ...rcom fr www majorcom fr 10 11 DPS 240S 360S 480S 720S DPS 240S 360S 480S 720S 9 PGM INPUT TERMINAL terminal block connector accepts the source input Please refer to the following picture about the sui...

Страница 7: ...100 70 Vrms 100V 70V SWITCH SPEAKER OUTPUT GND PGM PGM PGM INPUT TEMPERATURE DETECTION PROTECT MORE THAN 85 FAN START 65 FAN CONTROL FAN OCP OTP PROTECTION 4th ORDER LPF HV HV PWM GAIN 0 3dB PGM PRI...

Страница 8: ...r warranty provider as described in the warranty section of this manual Schematic A Schematic is available by contacting your warranty provider Parts List A Parts list is available by contacting your...

Страница 9: ...DPS 240S 360S 480S 720S 56 chemin de la Flamb re 31300 Toulouse FRANCE T l 3 3 0 5 6 1 3 1 8 6 8 7 F a x 3 3 0 5 6 1 3 1 8 7 7 3 commercial majorcom fr www majorcom fr User manual V1 1...

Отзывы: