background image

                                                

 

 

MTD30 

 

2000 COUNTS 

DIGITAL MULTIMETER 

 

  OPERATION MANUAL 

 

1.

   

SAFETY INFORMATION 

 

SAFETY SYMBOLS 
 

  Warning! 

Dangerous Voltage (Risk of electric shock). 

  Caution!

 Refer to the user’s manual before using this Meter. 

  Double Insulation 

(Protection Class 

). 

  Alternating Current (

AC

).

 

  Direct Current (

DC

).

 

  Either 

DC

 or 

AC

.

 

  Ground

 (maximum permitted voltage between terminal and ground). 

 

The

 

symbol indicates separate collection for electrical and electronic equipment. 

 

  The RESPONSIBLE BODY shall be made aware that, if the instrument 

is used in a manner not specified by the manufacturer, the protection 
provided by the instrument may be impaired. 

  The finger or any part of your body shall not be beyond the barrier of 

    the test probe when measuring. 

  Individual protective equipment must be used if HAZARDOUS LIVE parts in the 

installation where measurement is to be carried out could be ACCESSIBLE. 

 
The following safety information must be observed to insure maximum personal safety 
during the operation at this meter. 
 
 

Содержание MTD30

Страница 1: ...ection for electrical and electronic equipment The RESPONSIBLE BODY shall be made aware that if the instrument is used in a manner not specified by the manufacturer the protection provided by the instrument may be impaired The finger or any part of your body shall not be beyond the barrier of the test probe when measuring Individual protective equipment must be used if HAZARDOUS LIVE parts in the ...

Страница 2: ... data 1 8 Use the DMM indoor altitude up to 2000m and temperature 5 to 40 Maximum relative humidity 80 for temperatures up to 31 decreasing linearly to 50 relative humidity at 40 Pollution Degree 2 2 SPECIFICATIONS 2 1 GENERAL SPECIFICATIONS Display LCD with a max reading of 1999 Range control Manual range control Polarity Automatic negative polarity indication Zero adjustment Automatic Over range...

Страница 3: ...2 2 AC Voltage Range Accuracy Resolution 200V 1 5 3 100mV 500V 1V Average sensing calibrated to rms of sine wave Frequency 40 500Hz Overload protection 500V DC or AC rms Impedance 450kΩ 2 2 3 DC Current Range Accuracy Resolution 2000μA 1 5 2 1μA 20mA 10μA 200mA 2 0 2 100μA Overload protection F0 5A 600V fuse 2 2 4 Resistance Range Accuracy Resolution 200Ω 1 0 5 0 1Ω 2000Ω 1 0 3 1Ω 20kΩ 10Ω 200kΩ 1...

Страница 4: ...here the value of voltage is needed 3 Read the result from the LCD panel The polarity of the red lead connection will be indicated along with the DC voltage value Note a If the voltage range is not known beforehand set the selector switch to high range and work down b When 1 or 1 is display over range is being indicated and the selector switch must be set to a higher range c Don t apply more than ...

Страница 5: ...circuits 3 4 Resistance Measurement 1 Set the selector switch to desired Ω position 2 Connect tip of the test leads to the points where the value of the resistance is needed 3 Read the result from the LCD panel Note a If the resistance value being measured exceeds the maximum value of the range selected an over range indication will be displayed 1 select a higher range For resistance of approximat...

Страница 6: ...ttery need to changed 2 Before changing the battery set the selector switch to OFF position to power off 3 Remove the screw on the battery cover and lift the battery cover 4 Replace the old battery with the same type battery 5 Close the battery cover and fasten the screws Caution Dispose the used batteries according to the rules which are defined by each community Warning If an explosion or fire h...

Страница 7: ... case is closed 2 To avoid contamination or static damage do not touch the circuit board without proper static protection 3 If the meter is not going to be used for a long time take out the battery and do not store the meter in high temperature or high humidity environment 4 Repairs or servicing not covered in this manual should only be conducted by a qualified person 5 Periodically wipe the case ...