Страница 3: ...DC Voltage Measurement 11 4 3 AC Voltage Measurement 12 4 4 Frequency Measurement 13 4 5 LoZ AC Voltage Measurement 14 4 6 Resistance Measurement 15 4 7 Continuity Check 16 4 8 Diode Test 17 4 9 Capac...

Страница 4: ...ge 32 6 2 2 AC TRMS Voltage 33 6 2 3 LowZ AC TRMS Voltage 33 6 2 4 AC DC TRMS Voltage 33 6 2 5 LowZ AC DC TRMS Voltage 33 6 2 6 DC Current 34 6 2 7 AC TRMS Current 50Hz 60Hz 34 6 2 8 Flexible Coil Cur...

Страница 5: ...y with an analogue bargraph that provides fast sampling times and high accuracy measurements The meter has been designed to measure 1500V DC purposely for the Solar industry 1000V AC K Type temperatur...

Страница 6: ...nt in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation Overvoltage Category IV Equ...

Страница 7: ...tery Cover Lock 15 Battery Cover Never operate the meter unless the back cover and the battery and fuse covers are in place and fastened securely If the equipment is used in a manner not specified by...

Страница 8: ...E VFD Press the MODE key to switch the functions RANGE Press the RANGE key to manual range IR Press the IR key to switch DMM Mode and IR DMM Mode INRUSH Menu Enter function of the MENU or INRUSH selec...

Страница 9: ...nits and modifiers Button choices made in one function do not carry over into another function DC and AC DC Voltage Measurement Low Impedance Mode AC voltage Measurement Frequency and Duty Measurement...

Страница 10: ...nto the COM Input jack Insert the red test lead banana plug into the Positive Input jack 3 Press the MODE VFD Button to switch the DC Voltage functions 4 Read the Voltage in the display CAUTION Do not...

Страница 11: ...OM Input jack Insert the red test lead banana plug into the Positive Input jack 3 Press the MODE VFD Button to switch the AC DC Voltage functions 4 Read the AC DC Voltage in the display CAUTION Do not...

Страница 12: ...f Electrocution The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets As a result the reading ma...

Страница 13: ...Position 2 Insert the black test lead banana plug into the COM Input jack Insert the red test lead banana plug into the Positive Input jack 3 Read the Frequency in the display 4 Press the MODE VFD Bu...

Страница 14: ...tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets As a result the reading may show 0 volts when the o...

Страница 15: ...into the COM Input jack Insert the red test lead banana plug into the Positive Input jack 3 Read the Resistance in the display WARNING To avoid electric shock disconnect power to the unit under test a...

Страница 16: ...ack 3 Press the MODE VFD Button to switch the continuity functions 4 If the resistance is less than approximately 50 the audible signal will sound 5 If the circuit is open the display will indicate OL...

Страница 17: ...put jack Insert the red test lead banana plug into the Positive Input jack 3 Press the MODE VFD Button to switch the Diode functions Forward voltage will typically indicate 0 400 to 3 000V Reverse vol...

Страница 18: ...test lead banana plug into the Positive Input jack 3 Press the MODE VFD Button to switch the Capacitance functions 4 Read the Capacitance value in the Display WARNING To avoid electric shock disconne...

Страница 19: ...the function switch to the K Temp Position 2 Insert the Temperature Probe into the input jacks making sure to observe the correct polarity 3 Press the MODE VFD Button to switch the Unit C or F 4 Read...

Страница 20: ...Input jack Insert the red test lead banana plug into the Positive Input jack 4 Read the Current in the display 5 Press the MODE VFD Button to switch the AC and AC DC Current 6 Press the RANGE Button t...

Страница 21: ...surements up to 600A DC set the function switch to the 600A Position 3 For current measurements up to 1000A DC set the function switch to the 1000A Position 4 Press the MODE VFD Button to indicate on...

Страница 22: ...function switch to the 60A Position 2 For current measurements up to 600A AC set the function switch to the 600A Position 3 For current measurements up to 1000A AC set the function switch to the 1000A...

Страница 23: ...e function switch to the 60A or 600A 1000A Position 2 Press the INRUSH Button Enter key 2 second to indicate on the display Then measurement display 3 Clamp the cable to be motor 4 Start the motor 5 R...

Страница 24: ...old Relative Button to release freeze 4 17 Capturing Minimum and Maximum Values The MAX MIN Record mode captures minimum and maximum input values When the input goes below the recorded minimum value o...

Страница 25: ...Detector on a known live circuit to verify proper operation WARNING Insulation type and thickness distance from the source and other factors may effect operation always verify live voltage using othe...

Страница 26: ...s as show Press UP DOWN Button to select menu item or change the value of current focus item Press RIGHT MENU Button to enter the submenu or set focus on the current selected item Press LEFT Button to...

Страница 27: ...focus state use UP DOWN Button to change LCD s brightness use LEFT RIGHT MENU Button to exit focus state The available brightness s range is 100 to 10 in 10 steps Auto Power Off Press RIGHT MENU Butto...

Страница 28: ...system infomation menu This menu contains software s version hardware s version 5 2 5 Factory Set When select Factory Set option after press RIGHT MENU Button thedialog box will be displayed as show b...

Страница 29: ...ay Press the Button or key to select Record Item Press the Button Enter Record Menu In Record Menu Press the Button or key to select Sample Interval Item or Duration Item Press the Button Enter Record...

Страница 30: ...utton to stop record and Press the Button Save In Record Menu Press the Button or key to select Review Item Press the Button Enter View Record measurement Press the Button MODE key to Trend record and...

Страница 31: ...Xy where y max zoom dimension appears at the top of the display on the right side You can zoom X1 for at least 10 measuring points X2 for at least 20 measuring points X3 for at least 40 measuring poi...

Страница 32: ...6562ft Power Supply Battery Type 1 x 7 4V Rechargeable Li ion Battery 1200mAh Battery Charger Power Supply 100 240VAC 50 60Hz 12VDC 2A Low Battery Indication Symbol on the Display Auto Power Off Afte...

Страница 33: ...digits 300 0V 0 1V Range Resolution 6 2 3 LowZ AC TRMS Voltage Accuracy Input impedance 300K Protection against overcharge 1000VDC ACrms Accuracy specified from 10 to 100 of the measuring range sine...

Страница 34: ...e 100ms and reading for reference only 30 00A 0 01A 300 0A 0 1A 3 0 5 digits 3000A 1A Range Resolution 6 2 8 Flexible Coil Current 50Hz 400Hz Accuracy Protection against overcharge 1000ADC ACrms Accur...

Страница 35: ...cle Accuracy Pulse frequency range 40Hz 10kHz Pulse amplitude 5V 100us 100ms 60 00nF 0 01nF 3 0 20 digits 600 0nF 0 1nF 6 000 F 0 001 F 3 0 8 digits 60 00 F 0 01 F 600 0 F 0 1 F 6000 F 1 F 3 5 20 digi...