6.1. DC VOLTAGE MEASUREMENTS 

CAUTION:

  Do not measure DC voltages if a motor on the circuit is 

being switched ON or OFF. Large voltage surges may occur 
that can damage the meter.

1. Set the function switch to the "

VDC

" position. 

2. Insert the black test lead banana plug into the 

negative 

COM

 jack. Insert the red test lead 

banana plug into the positive 

V

 jack. 

3. Touch the black test probe tip to the negative 

side of the circuit. Touch the red test probe tip 
to the positive side of the circuit. 

4. Read the voltage on the display. 

6.2. AC VOLTAGE (FREQUENCY, DUTY CYCLE) MEASUREMENTS

CAUTION:

  Do not measure AC voltages if a motor on the circuit is 

being switched ON or OFF. Large voltage surges may occur 
that can damage the meter.

1.   Set the function switch to the green 

VAC/Hz/%

 

position. 

2.  Insert the black test lead banana plug into the 

negative 

COM 

jack. Insert red test lead banana 

plug into the positive 

V

 jack. 

3.   Touch the black test probe tip to the neutral side of 

the circuit. Touch the red test probe tip to the "live" 
side of the circuit. 

4.   Read the voltage on the display. 
5.   Press the 

MODE

 button to indicate "

Hz

". 

6.   Read the frequency in the display. 
7.   Press the 

MODE

 button again to indicate "

%

". 

8.   Read the % of duty cycle on the display. 

WARNING:

 Risk of Electrocution. The probe tips may not be long 

enough to contact the live parts inside some 240V outlets 
for appliances because the contacts are recessed deep in 
the outlets. As a result, the reading may show 0 volts 
when the outlet actually has voltage on it. Make sure the 
probe tips are touching the metal contacts inside the 
outlet before assuming that no voltage is present. 

Содержание MT1887 IV

Страница 1: ...INSTRUCTION MANUAL 1500V DC MULTIMETER IV MT1887...

Страница 2: ...2...

Страница 3: ...Cycle Measurement Electronic 13 6 11 4 20mA Measurements 13 6 12 Non Contact AC Voltage Measurements 13 6 13 Auto Ranging Manual Range Selection 14 6 14 Min Max 14 6 15 Relative Mode 14 6 16 Display B...

Страница 4: ...which the voltage with respect to earth ground exceeds in this case 1000 VAC or VDC This symbol adjacent to one or more terminals identifies them as being associated with ranges that may in normal us...

Страница 5: ...ter leads across a voltage source while the function switch is in the current resistance or diode mode Doing so can damage the meter 5 ALWAYS discharge filter capacitors in power supplies and disconne...

Страница 6: ...RANGE button 4 MODE Bluetooth button 5 Function switch 6 mA A and 10A input jacks 7 COM input jack 8 Positive input jack 9 HOLD and Backlight button 10 PEAK button 11 MAX MIN button Note Tilt stand an...

Страница 7: ...Autoranging Display hold Maximum Minimum Average Peak hold Relative Bluetooth 6 OPERATING INSTRUCTIONS WARNING Risk of electrocution High voltage circuits both AC and DC are very dangerous and should...

Страница 8: ...ge the meter 1 Set the function switch to the green VAC Hz position 2 Insert the black test lead banana plug into the negative COM jack Insert red test lead banana plug into the positive V jack 3 Touc...

Страница 9: ...DC set the function switch to the yellow mA position and insert the red test lead banana plug into the A mA jack 4 For current measurements up to 10A DC set the function switch to the yellow 10A HZ p...

Страница 10: ...nana plug into the A mA jack 4 For current measurements up to 10A AC set the function switch to the yellow 10A HZ position and insert the red test lead banana plug into the 10A jack 5 Press the MODE b...

Страница 11: ...is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 5 Read the resistance on the display 6 6 CONTINUITY CHECK WARNING To av...

Страница 12: ...rotary function switch to the CAP position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive V jack 3 Press the MODE button to...

Страница 13: ...EMENTS 1 Touch the probe tip to the live conductor or insert into the live side of the electrical outlet 2 If AC voltage is present the back light will flash a bright red 3 The auto off feature will t...

Страница 14: ...anges until you select the range you want 3 To exit the Manual Ranging mode and return to Auto ranging press and hold the RANGE key for 2 seconds Note Manual ranging does not apply for the Temperature...

Страница 15: ...attery should be replaced 6 18 MODE BLUETOOTH Press the MODE button to select AC or DC Frequency or Duty Cycle Resistance Continuity or Diode Test and C or F Bluetooth allows readings to be displayed...

Страница 16: ...s Multimeter is designed to provide years of dependable service if the following care instructions are performed 1 KEEP THE METER DRY If it gets wet wipe it off 2 USE AND STORE THE METER IN NORMAL TEM...

Страница 17: ...uses and batteries to make sure that they are still good and that they are properly inserted 17 7 2 REPLACING THE FUSES WARNING To avoid electric shock disconnect the test leads from any source of vol...

Страница 18: ...d from 5 of range to 100 of range 750HZ 1 5 reading 8 digits Range Resolution Accuracy 400 0mV 0 1mV 0 1 of reading 6 digits 4V 0 0001V 40V 0 001V 400V 0 01V 1500V 1 0V 0 1 of reading 6 digits 8 1 DC...

Страница 19: ...reading 10 digits 40mF 0 01mF Not specified 8 6 CAPACITANCE 19 Range Resolution Accuracy 40 00 400Hz 0 01Hz 0 5 reading 8 8 FREQUENCY ELECTRICAL Sensitivity 15V RMS 20 to 80 5A RMS Duty Cycle Not spe...

Страница 20: ...of reading 2 5 C 58 to 1832 F 1 F 1 0 of reading 4 5 F Meter only probe accuracy not included 8 10 TEMPERATURE TYPE K 0mA 25 4mA 0 20mA 100 24mA 125 Range Resolution Accuracy 25 to 125 0 01 50 digits...

Страница 21: ...correctly only on sine waves and they will read inaccurately on non sine wave or distorted signals True rms meters read accurately on either type of signal ACV Bandwidth 50Hz to 1000Hz Crest Factor 3...

Страница 22: ...cludes holster Size 187 x 81 x 50mm includes holster Safety This meter is intended for origin of installation use and protected against the users by double insulation per EN61010 1 and IEC61010 1 2nd...

Страница 23: ......

Страница 24: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: