Major tech MT1883 Скачать руководство пользователя страница 3

1. Safety Instructions

The following safety information must be read and understood to 
insure maximum personal safety during the operation of this meter:

Do not use the meter if the meter or test leads look damaged, or 
if you suspect that the meter is not operating properly.

Never ground yourself when taking electrical measurements. Do 
not touch exposed metal pipes, outlets, fixture, etc., which might 
be at ground potential. Keep your body isolated from ground by 
using dry clothing, rubber shoes, rubber mats or any approved 
insulating material.

Turn off power to the circuit under test before cutting, 
unsoldering, or breaking the circuit. Small amounts of current can 
be dangerous.

Use caution when working above 60V DC or 30C AC RMS, such 
voltages pose a shock hazard.

When using the probes, keep your fingers behind the finger 
guards on the probes.

Measuring voltage which exceeds the limits of the multimeter 
may damage the meter and expose the operator to a shock 
hazard. Always recognize the meter voltage limits as stated on 
the front of the meter

Never 

apply voltage or current to the meter that exceeds the specified 

maximum:

Input Protection Limits
Function
V DC/AC
mA DC/AC
A DC/AC

Frequency, Resistance, 
Capacitance, Diode Test, 
Continuity Temperature

Maximum Input
1000V DC, 700V AC
200mA

20A DC/AC (30 seconds max every 15 min)

250V DC/AC

3

Содержание MT1883

Страница 1: ...MT1883 Manual Ranging Multimeter INSTRUCTION MANUAL...

Страница 2: ...urement 9 4 3 AC Voltage Measurement 9 4 4 DC Current Measurement 10 4 5 AC Current Measurement 10 4 6 Resistance Measurement 11 4 7 Continuity Check 11 4 8 Diode Test 11 4 9 Frequency Measurement 12...

Страница 3: ...t under test before cutting unsoldering or breaking the circuit Small amounts of current can be dangerous Use caution when working above 60V DC or 30C AC RMS such voltages pose a shock hazard When usi...

Страница 4: ...on which if not avoided may result in damage to the product This symbol advises the user that the terminal s so marked must not be connected to a circuit point at which the voltage with respect to ear...

Страница 5: ...lay with function indication Polarity Automatic negative polarity indication Overrange OL mark indication Low Battery Indication The is displayed when the battery voltage drops below the operating lev...

Страница 6: ...50V and 20A 250V fuse Maximum Input 200mA DC or 200mA AC RMS on mA ranges 20A DC or AC RMS on 20A range Range Resolution Accuracy 200 0mV 0 1mV 2 000V 1mV 20 00V 10mV 200 0V 100mV 1000V 1V 0 5 of rdg...

Страница 7: ...250V AC RMS Range Resolution Accuracy 2 000mA 1uA 200 0mA 100uA 20 00A 10mA 2 0 of rdg 3 dgts 1 2 of rdg 3 dgts 3 0 of rdg 10 dgts Range Resolution Accuracy 200 0 0 1 2 000k 1 20 00k 10 200 0k 100 2 0...

Страница 8: ...RMS 4 Operation Warning Risk of electrocution High voltage circuits both AC and DC are very dangerous and should be measured with great care If 1 appears in the display during a measurement the value...

Страница 9: ...and value If the polarity is reverse the display will show minus before the value 4 3 AC Voltage Measurements Warning Risk of electrocution The probe tips may not be long enough to contact the live p...

Страница 10: ...r to the circuit 7 Read the current on the display The display will indicate the proper decimal point value 4 5 AC Current Measurement Warning To avoid electric shock do not measure AC current on any...

Страница 11: ...the display The display will indicate the proper decimal point value 4 7 Continuity Check Warning To avoid electric shock never measure continuity on circuits or wires that have voltage on them 1 Set...

Страница 12: ...y The digital reading will indicate the proper decimal point value 4 10 Capacitance Measurements Warning To avoid electric shock disconnect power to the unit under test and discharge all capacitors be...

Страница 13: ...omes at or drops below the operating voltage BAT will appear in the right hand side of the LCD display The battery should be replaced 2 Follow instructions for installing the battery See the battery i...

Страница 14: ...y item under test 2 Open the back cover by loosening the screw on the back cover using a phillips head screwdriver 3 Remove the old fuse from its holder by gently pulling it out 4 Install the new fuse...

Страница 15: ......

Страница 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: